Hood Exhaust - GE CVM2072 Installation Instructions Manual

Over the range microwave oven
Hide thumbs Also See for CVM2072:
Table of Contents

Advertisement

Installation
Instructions
HOOD EXHAUST
NOTE:
Read
these
next
two
pages
tufty if you
plan
to vent
your
exhaust
to the
outside.
If you
plan
to recirculate
the
air back
into
the
room,
proceed
to page
6.
OUTSIDE
TOP EXHAUST
(EXAMPLE
ONLY)
The
following
chart
describes
an example
ot one
possible
ductwork
installation.
DUCT PIECES
EQUIVALENT
NUMBER
LENGTH
x
USED
RoofCap
24 Ft.
x
12 Ft.Straight Duct
12 Ft.
x
(6" Round)
-_
Rectangular-to-Round
5 Ft.
x
TransitionAdaptor*
Equivalent l engthsof duct piecesare basedon actualtests and
reflect requirements for goodventingperformance with anyvent hood.
(1)
(1)
(1)
Total
Length
EQUIVALENT
LENGTH
24 Ft.
12 Ft.
5 Ft.
41 Ft.
* IMPORTANT:
If a rectangulat_to-round
transition
adaptor
is used,
the
bottom
cornets
of the
damper
will
haxe
to be
cut
to fit,
usin,,._ the
tin
snips,
in order
to allow
free
moxement
of the
damper.
OUTSIDE
BACK EXHAUST
(EXAMPLE
ONLY)
The
following
chart
describes
an
example
ot one
possible
ductwork
installation.
[
DUC_
PIECES
_Wall
Cap
(_
90° Elbow
EQUIVALENT
NUMBER
LENGTH*
x
USED
40 Ft.
x
(1)
3 Ft.
x
(1)
3 Ft.StraightDuct
3W' x 10" Rectangular)
10 Ft.
x
(2)
EQUIVALENT
LENGTH
40 Ft.
3 Ft.
20Ft.
Equivalent lengths of duct pieces are based on actual tests and
reflect requirements for good venting performance with any vent hood.
Total Length
=
63 Ft.
NOTE:
For back exhaust,
care should
be taken
to align
exhaust
with space
between
studs,
or wall should
be prepared
at the time it is const_ ucted
by leaving
enough
space
between
the wall studs
to accommodate
exhaust.
4

Advertisement

Table of Contents
loading

Table of Contents