Installation instructions
NOTE:
If you need
to install
ducts,
note
that the total
duct length
of 3¼" x 10" rectangular
or 6" diameter
round
duct should
not exceed
140 equivalent
feet.
Outside
ventilation
requires
a HOOD
EXHAUST
DUCT.
Read
the fbllowing
careflflly:
NOTE:
It is important
that venting
be installed
using
the most
direct
route
and
with as few elbows as possible.
This ensures
clear
venting
of exhaust
and helps
prevent
blockages.
Also, make
sure dampers
swing freely
and
nothing
is blocMng
the ducts.
Exhaust connection:
The hood exhaust has been designed
to mate with
a standard
3¼" x 10" rectangular
duct.
If a round
duct is required,
a rectangular-to-round
transition
adaptor
must
be used. Do not use less than
a 6" diameter
duct.
Maximum
duct length:
For safisfhctory
air movement,
the total duct length
of
3¼"x
10" rectangular
or 6" diameter
round
duct should
not exceed
140 equivalent
feet.
Elbows, transitions,
wall and roof caps, etc.,
present
additional
resistance
to airflow
and are equivalent
to a section
of straight
duct which
is longer
than
their
actual
physical
size. When
calculating
the total duct
length,
add
the equNa/ent
lengths
of all transitions
and
adaptors
plus the length
of all straight
duct sections.
The
chart below
shows you how to calculate
total
equiwdent
ducta, vork length
using the approximate
feet
of equivalent
length
of some
typical
ducts.
DUCT PIECES
&
Rectangular-to-Round
TransitionAdaptoP
Wall Cap
90° Elbow
EQUIVALENT
LENGTH
5 Ft.
40 Ft.
10 Ft.
X
NUMBER
USED
( )
( )
( )
EQUIVALENT
LENGTH
Ft.
Ft.
Ft.
45° Elbow
5 Ft.
x
(
)
=
Ft.
90° Elbow
25 Ft.
x
(
)
=
Ft.
45° Elbow
5 Ft.
x
(
)
=
Ft.
Roof Cap
24 Ft.
x
(
)
=
Ft.
Straight Duct 6" Round or
1 Ft.
x
(
)
=
Ft.
3X" x 10" Rectangular
Total Ductwork
=
Ft.
* IMPORTANT:
If a rectangula>to-round
transition
adaptor
is used,
the bottom
corners
of the damper
will ha_e to be cut to fit, using
the tin snips, in
order
to allow ti'ee movement
of the damper.
Equivalent
lengths
of duct
pieces
are based
on actual
tests
and
reflect
requirements
for good
velltillg
performance
x_dth any
Vellt
hood.
5