Installation
Instructions
ELECTRICAL CONNECTIONS
_7
Remove
house
fuse or open
circuit
breaker.
[]
B]
Loosen
screws
for the junction
box cover
and rotate
out of place
or remove
the
cover.
Examine
the junction
box location
to
determine
the best routing
of the conduit,
and select
the best available
7/8"
diameter
knockout.
Avoid
using
holes
in the top of
the junction
box to prevent
the conduit
from
interfering
with
the back of the
range.
Break open the selected
knockout
by
placing
a bladed
screwdriver
on the
scored
opening
in the junction
box and
striking
the screwdriver
with
a hammer.
(Pliers
may be required
to complete
the
removal
of the knockout.)
7/8"
knockout
Cover rotated from
box opening
Position
the range
in front
of the opening,
but slightly
to the side,
in a manner
so
that
a person
can enter
the opening
to
wire
the range to the
house
wiring
in
the junction
box.
Feed wires
and conduit
through
the open
hole and snap the conduit
fitting
into the
hole.
Route the conduit
in a manner
that
will
not interfere
with
the rear wire
cover.
The conduit
must
be routed
below
the
wire
cover.
WARNING:
Improper
connection
of aluminum
house wiring
to copper leads can
result in an electrical
hazard
or fire. Use only
connectors
designed
for joining
copper to
aluminum
and follow
the manufacturer's
recommended
procedure
closely.
GENERAL
NOTE FOR ALL WIRE NUT
APPLICATIONS:
THE PROPER SIZE WIRE NUT
SHALL BE PLACED OVER THE STRIPPED
LEADS AND THE WIRE NUT
TWISTED
UNTIL
THE WIRE NUT CAN NOT BE PULLED
FROM
THE LEADS. NO CONDUCTOR
SHALL BE
EXPOSED
IN THE CONNECTION.
THE
EXCEPTION
TO THE CONDUCTOR
BEING
EXPOSED
IS THE BARE COPPER GROUND
CONNECTION.
BREAKER
OR FUSE SIZE
240V
40 Amps
+
208V
40 Amps
+
+ NOTE: Check Local Codes for
required
breaker
size.
6