Operation Checklist - GE ZET1 Installation Instructions Manual

30" {76.2 cm) built-ln wall oven
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
Pre-Test Checklist
Remove all protective film, if present, and
any stickers,
Check to be sure that all wiring is secure and
not pinched or in contact with moving parts,
NOTE TO ELECTRICIAN: You must unplug
the green wire (near where the long flexible
conduit exits the unit} when conducting
high-potential
testing.
Please replug prior
to operation.
Check that the bottom trim is installed prop-
erly (seepage 12).
Check to be sure the mounting screws are
installed and flush with the side trim (see
page 11).
Operation Checklist
Remove all items from the inside
of the oven,
Check that conduit is securely connected to
the junction box.
Turn on the power to the oven. (Referto your
Owner's Manual.) Verify that the bake and
broil units, and all cooking functions operate
properly,
Check that the circuit breaker is not tripped
nor the house fuse blown,
Seeyour Owner's Manual for
troubleshooting list.
If"bAd .... LinE" appears in the display when
the power is turned on, the house wiring
connections are incorrect.
PROBE
TIMER
CLOCK
COOK
DELAy
TiME
START
NOTETO ELECTRICIAN: The power leads
supplied with this appliance are UL
recognized for connections to larger gauge
household wiring. The insulation of these
leads is rated at temperatures much higher
than the temperature rating of household
wiring. The current carrying capacity of a
conductor
is governed by the wire gauge and also
the temperature rating of the insulation
around the wire.
NOTE: ALUMtNUM WIRING
A.
B.
WARNING: IMPROPER
CONNECTION OF ALUMINUM HOUSE
WIRING TO THE COPPER LEADS CAN
RESULT INAN ELECTRICALHAZARD OR
FIRE.
Splice copper wires to aluminum wiring
using special connectors designed
and UL approved for joining copper to
aluminum,
and follow the manufacturer's
recommended connector procedure
closely.
NOTE:Wire used, location and
enclosure of splices, etc., must conform
to good wiring practice and local codes.