GE ZVC42L1SS Installation Instructions Manual page 8

Custom hood inserts
Table of Contents

Advertisement

Available languages

Available languages

Design Information
PRODUCT
DIMENSIONS
ZVC48
Dimensions
and Specifications
lin inches}
Outside Dimensions
I"
39-1/2"
O
The custom canopy must be sized to fit the insert
sleeve. Construct
the canopy with an opening
that is:
38-3/4"W
x 13-3/16"D
The opening must be constructed
of 3/4" thick
material to ollow the sleeve locking clips to
engage.
The Supplied Liner
The stoinless steel liner is shipped with eoch hood
insert. This non-combustible
liner protects the
underside of the conopy.
Custom Liner
If you ore not using the supplied liner, you may
construct
c] custom non-combustible
liner. Use the
supplied
liner c]s c] templote.
The opening
must be
38-3/4"W
x 13-3/16"D.
3/4" thick moterial must
surround
the opening to allow the sleeve locking
clips to engage. The insert sleeve inside the cobinet
should be positioned
1/2" from the reor wall so
thot the center of the 8" duct is 5-1/2" from the
reor woll.
The Insert Sleeve
13"
1/2"
A 1/2" wide flc]nge surrounds
the outside edge of
the insert sleeve.
Remote Location
for the Control
The control may be removed from the hood
c]nd installed into c] wc]ll or countertop.
A 30-ft.
length of wire is supplied to occommodote
most
instc]llc]tions. A blanking plc]te covers the opening
when the controls ore removed.
The overall size of the control
is 4-1/4" wide and
2-1/4" deep.
1-11/1["
3-11/1e"
Control cutout
We recommend
that the cutout in granite or other
hard surfaces be made before the countertop
is
installed.