DUCT FITTINGS
Use this chart to compute
maximum
permissible
lengths for
duct runs to outdoors.
NOTE: Do not exceed maximum
permissible equivalent
lengths!
Maximum
duct length:
100 foot for range hoods.
Flexible ducting:
If flexible metal ducting
is used,
all the equivalent
feet values
in the table should be doubled.
The flexible metal duct should
be straight
and smooth and
extended as much as possible.
DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation
hood, may interrupt the proper
flow of combustion
air and
exhaust required by fireplaces,
gas furnaces, gas water heaters
and other naturally vented
systems. To minimize the chance
of interruption
of such naturally
vented systems, follow the heating
equipment manufacturer's
guidelines and safety standards
such as those published by NFPA
and ASHRAE.
Equivalent
Duct Piece
Dimensions
Length*
Round,
1 ft.
straight
(per foot
length)
3-!/4"
x 12"
1 ft.
straight
(per foot
length)
17 ft.
90 ° elbow
!0 ft.
45 ° elbow
3-1/4" x 12"
90 ° elbow
43 ft.
3-i/4"
x 12"
45 ° elbow
26 ft.
_
3-i/4"x12"
90 ° flat elbow
102 ft.
8" round to
3-!/4"
x 12" transition
2 ft.
__
3-i/4"
x 12" to 8"
round transition
5 ft.
8" round
to 3-i/4"
x 12"
transition
90 ° elbow
6 ft.
3-1/4" x 12" to 8"
round transition
90 ° elbow
13 ft.
Round
wall cap
with damper
32 ft.
3-!/4"
x !2" wall cap
with damper
75 ft.
Round
roof cap
44 ft.
Total
guantity
Equivalent
Used
Length
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Total Duct Run
10