Duct Fittings - GE ZVC36L2SS Installation Instructions Manual

Custom hood inserts
Table of Contents

Advertisement

Available languages

Available languages

Advance Planning
DUCT FITTINGS
Use this chart to compute
maximum
permissible
lengths
for duct runs to outdoors.
NOTE: Do not exceed maximum
permissible
equivalent lengths!
Maximum
duct length:
100 foot for range hoods.
Flexible ducting:
If flexible metal ducting
is used,
all the equivalent
feet values in
the table should be doubled.
The flexible metal duct should
be straight
and smooth and
extended as much as possible.
DO NOT use flexible plastic
ducting.
NOTE: Ang home ventilation
sgstem, such as a ventilation
hood,
may interrupt the proper flow of
combustion
air and exhaust
required by fireplaces, gas
furnaces, gas water heaters and
other naturallbl vented Sblstems.
To minimize the chance of
interruption
of such naturallbl
vented sgstems, follow the
heating equipment manufacturer's
guidelines and safetbl standards
such as those published bbl NFPA
and ASHRAE.
Duct Piece
Dimensions
Round,
straight
Equivalent
Length*
1ft.
(per foot
length)
3-1/4" x 12"
1 ft.
straight
(per foot
length)
Quantity
Used
17 ft.
90 ° elbow
10 ft.
45 ° elbow
3-P'4" x 12"
90 ° elbow
43 ft.
3-1/4" x 12"
45 ° elbow
26 ft.
3-1/4" x 12"
90 ° flat elbow
102 ft.
8" round to
3-1/4" x 12" transition
2 ft.
__
3-1/4" x 12" to 8"
round transition
5 ft.
8" round
to 3-1/4" x 12"
transition 90° elbow
6 ft.
3-1/4" x 12" to 8"
round transition 90 ° elbow
13 ft.
Round
wall cap
with damper
32 ft.
3-1/4" x 12" wall cap
with damper
75 ft.
<_
Round
roof cap
44 ft.
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Total Duct Run
Total
Equivalent
Length
10