Water pressure of 20 to 120 psi is required to correctly fill
the washer in the proper time. Pressuresof less than 20 p.s.i.
may cause a failure in the water valve or the fill times to be
extended past what the washer controls will normally allow.
The water valve may also not shut off completely. Hot and
Cold water faucets must be within 4 feet of the back of the
washer for the inlet hoses provided with the washer.
FAUCETS SHOULD BE EASILY ACCESSIBLE AND
TURNED OFF WHEN WASHER IS NOT IN USE TO
AVOID THE POSSIBILITY OF WATER DAMAGE.
NOTE: A ccessory inlet hoses are available in various lengths up to 10 feet for faucets more than 4 feet from the back of the washer.
Recommended heightof the standpipeis 36". Thedrain hosemust be routedthroughthe drain hoseclip to the standpipe.Standpipemust
be largeenoughto acceptthe outsidediameterof the drain hose.The drain hoseis attachedto the machineat the factory.
Forbest performancethe washer must be installedon a solidlyconstructedfloor.Woodfloors may needto be reinforcedto minimizevibration
and/or unbalancedload situations.Carpeting and soft tile surfacesare contributingfactors in vibration and/ortendencyfor a washerto move
slightly duringthe spin cycle.Neverinstall the washeron a platformor weaklysupportedstructure.
MINIMUMCLEARANCES
FORCLOSET A NDALCOVE INSTALLATIONS:
Sides- 0 in. Rear- 1 1/2 in. Top- 2 in. ClosetFront- 0 in.The
closetfront must havea total unobstructed air openingof 72 sq. in.
minimum. A Iouvereddoor with equivalentair openingis acceptable.

Advertisement