5. Use %"nutdriver toconnect theneutral (white) wire tothe
2. Use %"nutdriver t oconnect theneutral (white) wire tothe
center terminal block post w ithoneofthe10-32 hexnuts.
center terminal block post w ithone ofthe10-32 hexnuts.
F
B
D
A. 10-32 hex nut
B. Ground-link
screw
C. Line ! (black)
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
6=
7.
Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1%" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Replace terminal block access cover.
3-wire connection:
Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief in the
cord/conduit
plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
E
C
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Neutral (white) wire
E. Line 2 (red)
3=
4.
Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1%" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Replace terminal block access cover.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect
or
circuit breaker box. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Power supply cord wires
(7.6 cm)
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire Connection:
Direct Wire
Use this method for:
New branch-circuit
installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral