24" (61 cm) electric built-in oven
Hide thumbs Also See for IBS324PSW1:

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
24" (61 CM) ELECTRIC BUILT-INOVEN
INSTRUCTIONS D'INSTALLATION
FOUR ELECTRIQUE ENCASTREDE 24" (61 CM)
Table of Contents / Table des mati_res
BUILT-IN OVEN SAFETY .................................
1
.................. 2
Tools and Parts .............................................
2
Location Requirements .................................
2
................................ 3
.................... 4
Prepare Built-In Oven ....................................
4
Remove Oven Door .......................................
4
Make Electrical Connection .......................... 4
Install Oven ....................................................
5
Complete Installation ....................................
6
SI_CURITI_ DU FOUR ENCASTRI_ .................. 7
....................... 7
Outillage et pieces .........................................
7
Exigences d'emplacement
............................ 7
electriques .............................. 8
................. 9
Preparation du four encastre ......................... 9
D_pose de la porte du four ............................ 9
electriq ue ............................ 10
Installation du four .......................................
11
Achever I'installation .................................... 12
BUILT-INOVEN SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT
: A
conserver pour consultation par I'inspecteur local des installations 61ectriques.
501910200218

Advertisement

loading
Need help?

Need help?

Do you have a question about the IBS324PSW1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IKEA IBS324PSW1

  • Page 1: Table Of Contents

    INSTALLATION INSTRUCTIONS 24" (61 CM) ELECTRIC BUILT-INOVEN INSTRUCTIONS D'INSTALLATION FOUR ELECTRIQUE ENCASTREDE 24" (61 CM) Table of Contents / Table des mati_res SI_CURITI_ DU FOUR ENCASTRI_ ....7 BUILT-IN OVEN SAFETY ......... INSTALLATION REQUIREMENTS ....2 EXIGENCES D'INSTALLATION ....... 7 Tools and Parts ..........
  • Page 2: Installationrequirements

    INSTALLATIONREQUIREMENTS Undercounter Installation (with cooktop installed above): s c nd Js(xds Ovens approved for this type of installation have an approval label located on the top of the oven. Refer to undercounter installation Gather the required tools and parts before starting installation. instructions for cutout dimensions and approved oven cooktop Read and follow the instructions provided with any tools listed...
  • Page 3 Oven Installed in Cabinet It is not recommended to have a fuse in the neutral or ground circuit. This oven must be connected to a grounded metal, permanent wiring system. Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical...
  • Page 4: Installationinstructions

    Meek® E®c c<s Co s sect _,,_F,,_ _ _ ',%: _ _,_ ..NOTE: The IKEA® Column Cabinet is available for installation but not required. The oven may also be installed into custom cabinets. 1. Decide on the final location for the oven. Excessive Weight Hazard Use two or more people to move and install oven.
  • Page 5 Connect the 2 red wires (G) together using a UL listed wire 4-Wire Cable fromHomePower S upply connector. Install junction box cover. IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through Ove s neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction...
  • Page 6 3. Push against seal area of front frame to push oven into 10. Replace oven door by inserting both hanger arms into the cabinet, door. Securely fasten oven to cabinet using the four #8-14 x 1" screws provided. Insert the screws through holes in mounting rails.
  • Page 7: Exigences D'installation

    SECURITE DU FOUR ENCASTRE Votre securite et celle des autres est trbs importante. Nous donnons de nombreux messages de s6curit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous toujours lire tousles messages de s6curit6 et de vous y conformer. Ce symbole d'alerte de s6curit6 vous signale les dangers potentiels de d6ces et de blessures graves &...
  • Page 8 Installation sous un plan de travail (avec table de cuisson Four simple install6 dans un placard install_e au-dessus) : Les fours homologu6s pour ce type d'installation comportent etiquette d'homologation placee sur le dessus du four. Voir les instructions d'installation du plan de travail au sujet des dimensions de I'ouverture &...
  • Page 9: Instructions D'installation

    Iocaux. Pour obtenir un exemplaire de la norme des codes ci-dessus, contacter : REIVlAROUE : Le placard a colonne IKEA® est recommand@ pour National Fire Protection Association I'installation mais n'est pas indispensable. Le four peut aussi @tre install@ dans des placards personnalis@s.
  • Page 10: Raccordement Electrique

    Tableau des options de raccordement 61ectrique Voir la section : C&blage de la maison : 4 conducteurs C&ble & 4 conducteurs depuis le point de distribution du domicile Risque de choc _lectrique D_connecter la source de courant _lectrique avant d'entreprendre le travail.
  • Page 11 A I'aide de deux personnes ou plus, soulever le four par les C&ble & 3 conducteurs depuis le point de distribution du poignees laterales situ6es de chaque c6te du four. Inserer domicile - I_.-U. seulement delicatement le four dans I'ouverture du placard. IMPORTANT : Utiliser le c&ble &...
  • Page 12 501910200218 11/06 © 2006. All rights reserved. ® IKEA is a registered trademark of Inter-lkea Systems B.V. Printed in Italy Tous droits reserves. ® IKEA est une marque deposee de Inter-lkea Systems B.V. Imprime en Italie...

This manual is also suitable for:

Ibs124pss1Ibs324psw00Ibs224psm1