Gas Conversions - Jenn-Air JGCP430 Installation Instructions Manual

30" (76.2 cm), 36" (91.4 cm), 48" (121.9 cm) commercial style gas cooktops
Hide thumbs Also See for JGCP430:
Table of Contents

Advertisement

Available languages

Available languages

18. Set the control console back into place on the cooktop. For a
proper fit, the flange of the control console must hook over
the lip on the front of the cooktop.
19. Check that the control console is flush with the top edge of
the cooktop.
B
A. Control console flange
B. Front lip of range cooktop
A. Flush with top of cooktop
20. Replace the 2 screws on each side of the control console.
21. Push the cooktop back into place in the cutout.
22. Replace the control knobs.
23. Replace burner grates.
24. Plug in cooktop or reconnect power.
25. Test the flame by turning the control from LO to HI, checking
the flame at each setting.
GAS CONVERSIONS
IMPORTANT:
Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
Explosion Hazard
Use a new CSA International
approved
gas supply line.
Install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company
personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
1. Turn the manual shutoff valve to the closed position.
.......... ..................
S
A_ J
..............
.....................
C
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect
power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "NAT" or "LP" position. Turn over the spring
retainer so the "LP" is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
jiJ_
A
T,
B
E
D
C
A. Access cap
D. LP position
B. Gasket
E. NAT position
C. Gas pressure regulator
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jgcp436Jgcp536Jgcp548

Table of Contents