FOR YOUR SAFETY: • You will need TWO people to install this oven. It is heavy and could cause personal injury if not handled properly. The dimensions of the oven are as follows: MODEL NO : 721.67600, 721.67601,721.67602, 721.67680, 721.67681,721.67682 Height :16...
Page 3
YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! - If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
Page 4
YOUR SAFETY FIRST • MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. - Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath. - ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2"...
PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts. One power cord clamp and Damper/duct connector One dark-colored mounting screw (to hold the power cord) (for roof-venting or wall-venting installation) Actual Size Not Actual Size...
Page 6
PARTS, TOOLS, MATERIALS YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THE INSTALLATION: Carton or other heaw material for covering the counter top. Stud finder or thin nail. Clear tape (for taping the templates to the wall) Key hole saw (for the power cord hole) Saber saw (for cutting vent hloes for roof or wall venting) Electric drill...
Page 7
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS WARNING AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail. NOTE: The outlet should be on a circuit dedicated to the Cabinet microwave oven 120volt, 60Hz., AC only, with a Upper...
STEP 2: PREPARE THE VENTING SYSTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length Sears recommends are shown in Figure 9, page 9. WARNING-FIRE HAZARD THIS OVEN MUST BE PROPERLY VENTED! You may vent your oven in one of three ways: Roof-venting If your oven is located on an outside wall near the roof, as in Figures 6 (31/4"...
Page 9
STEP 2: PREPARE THE VENTING S YSYTEM STANDARD FITTINGS NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper sticking.
STEP 3: PREPARE THE VENTING BLOWER Your microwave oven is shipped with the blower assembled for roof venting. You need to adjust the blower you want wall-venting or room-vented (recirculating) installation. WARNING ELECTRICAL SHOCK HAZARD! • DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result in electrical shock.
Page 11
STEP 3: PREPARE THE VENTING BLOWER blower plate mounting screws Use side cutters or tin snips. blower unit exhaust ports blower blower. plate blower unit Knockouts "B" mounting screw Figure 14 Figure 15 blower blower plate ROOM-VENTED (Recirculating) screws INSTALLATION: 1.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION BEFORE YOU START 1. Remove any shipping materials and parts from inside the microwave oveR. 2. Cover the counter top or cooktop with a thick, protective A thick, protective covering to protect it from damage and dirt. See Figure covering NOTE: If you have a free-standing range, disconnect it,...
Page 13
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION DRILL THE HOLES IN THE WALL AND UPPER CABINET. WARNING BE VERY CAREFUL WHEN DRILLING HOLES INTO THE WALL. Electrical wires could be concealed behind the wall covering and if the drill hits them you could get an electric shock. 1.
STEP 5: INSTALL THE MOUNTING PLATE 1. Remove the upper cabinet and wall templates. mounting plate NOTE: If you are venting the oven through the wall, be sure you align the damper/connector on the rear of the mounting plate with the 3 1/4"x10" duct.
Page 15
STEP 6: ATTACH THE OVEN TO THE WARNING You will need two people to lift this microwave. Failure to use more than one person could result in personal injury. 1. Carefully lift microwave oven and hang it on support tabs (See Figure 26) at the bottom of the mounting plate.
STEP 6: ATTACH THE OVEN TO THE WALL 6. Roof-vented installation: Align the damper/duct connector N" ///] with the vent on top of the microwave oven. Damper damper should be on top of tab. Use two tapping screws(bright- colored) to attach damper/duct connector to the microwave oven.
Installtion Instructions For in-house major brand repair service Call 24 hours a day, 7 days a week 1-800-4-REPAIR Model No. (1-800-473-7247) Para pedir servicio de reparaci6n a 721.67600 domicilio-1-800-676-5811 721.67601 721.67602 721.67680 721.67681 For the location a 721.67682 Sears Parts and Repair Center in your area...
Need help?
Do you have a question about the 721.67600 and is the answer not in the manual?
Questions and answers