Download Print this page

Kenmore 79078023300 Installation Instructions Manual page 6

30" gas range

Advertisement

Available languages

Available languages

Electrical
Requirements
120 volt, 60 Hertz,
properly
grounded
dedicated
circuit
protected
by a 15 amp circuit
breaker
or time delay
fuse.
Note:
Not recommended
to be installed
with a Ground
Fault Interrupt (GFI).
Do not use an extension
cord wlfh fhls range.
Grounding
Insfrucfions
IMPORTANT
Please read carefully.
For personal
safety, fhls appliance
must be properly
grounded.
The power cord of this appliance
is equipped
with a
3=prong (grounding) plug which mates with a standard
3=prong grounding
wall receptacle
(see Figure 6) to
minimize
the possibility
of electric
shock hazard
from the
appliance.
The wall receptacle
and circuit
should
be checked
by
a qualified
electrician
to make
sure the receptacle
is
properly
grounded.
Preferred
Method
Grounding
type
wall
receptacle
Do not, under any
circumstances,
cut,
remove,
or bypass
the grounding
prong.
Assembly
of the Burner
Caps and Burner
Grates
Refer to the Use and Care Guide
packaged
with the
cooktop
for operating
instructions and for care and
cleaning
of your cooktop.
_Do
not touch the burners.
They may
be hot enough
to cause burns.
Install
Burner
Caps
This cooktop
is equipped
with sealed
burners.
Aii pieces
are at their place. Take note where they are. Remove
all packaging
material.
Make
sure the burner caps
are properly
aligned
and leveled.
The burner
cap lip
(See Figure 7) should fit snug into the center of burner
head and rest level. Refer to Figures 8 & 9 for correct
and incorrect
burner cap placement.
Once
in place,
you may check the fit by gently
sliding
the burner
cap
from side to side (Figure 10) to be sure it is centered
and firmly
seated.
When
the burner cap lip makes
contact
inside the center
of the burner head you will be
able to feel it. Please note that the burner
cap should
NOT
move
off
the center
of the burner
head when
sliding
from side to side. NOTE: There are no burner
adjustments
necessary
on this cooktop.
Power supply cord with
3=prong grounding
plug.
Figure 6
Burner Head
Fig. 7
Where
a standard
2-prong
wall receptacle
is installed,
it is the personal
responsibility
and obligation
of the
consumer
to have it replaced
by a properly
grounded
3=prong
wall receptacle.
Do not, under any circumstances,
cur or remove
fhe
fhlrd
(ground)
prong from fhe power cord.
Disconnect
electrical
supply
cord
from
wall receptacle
before
servicing
cooktop.
Correct Burner Cap
Placement
= Fig. 8
incorrect
Burner Cap
Placement
= Fig. 9
Fig. 10