A clothes dryer must be exhausted
outdoors.
Do not
exhaust dryer into a chimney, a wail, a ceiling,
an attic,
a crawl space or any concealed
space of a building.
A
clothes dryer
produces combustible
lint. If the dryer is
not exhausted
outdoors,
some fine lint will be expelled
into the laundry
area. An accumulation
of lint in any
area of the home can create
a health and fire hazard.
ii
The dryer must be connected
to an exhaust outdoors.
Regularly
inspect the outdoor
exhaust opening
and remove
any accumulation
of lint around the outdoor
exhaust
opening
and in the surrounding
area.
FIRE HAZARD
*
Do not allow combustible
materials
(for example:
clothing,
draperies/curtains,
paper)
to
come
in
contact
with exhaust system. The dryer MUST NOT
be exhausted
into a chimney, a wall, a ceiling, or any
concealed
space of a building
which can accumulate
:
lint, resulting
in a fire hazard.
*
Do not screen the exhaust ends of the vent system, or
ii
use any screws, rivets or other fasteners that extend
ii
into the duct to assemble the exhaust system. Lint can
:
become
caught
in the screen, on the screws or rivets,
clogging
the duct work and creating
a fire hazard
:
as weii as increasing drying times. Use an approved
vent hood to terminate
the duct outdoors,
and seal
ii
aii joints with metal foil duct tape. Aii male duct pipe
ii
fittings
MUST be installed
downstream
with the flow
of air.
RNING .........................................................................................
FIRE H AZARD
.....
Exceeding
the length of duct pipe or number
of elbows
allowed
in the "MAXIMUM
LENGTH"
charts can cause
an accumulation
of lint in the exhaust system. Plugging
the system could create a fire hazard, as well as
MAXIMUM
LENGTH
of 4" (102 ram)
Rigid
Metal
Duct
Z
VENT
HOOD
TYPE
(Preferred)
0-
/0
0
4 _
(10.2cm)
Iouvered
0
64 ft. (19.5 m)
1
52 ft. (15.9 m)
2
44
ft. (13.5 m)
3
32 ft. (9.8 m)
4
28 ft. (9.5 m)
2.5"
(6.35cm)
48 ft. (14.6
m)
40 ft. (12.2 m)
32 ft. (9.8 m)
24 ft. (7.3 m)
16 ft. (4.9 m)
WA.N NG ...............
FIRE HAZARD
*
Do not install flexible
plastic or flexible
foil venting
material.
*
If installing
semi-rigid
venting, do not exceed 8 ft.
Exhaust direction
Directional
exhausting
can be accomplished
by installing
a quick-turn
90 ° dryer vent elbow directly
to the exhaust
outlet of dryer. Dryer vent elbows are available
through
your local parts distributor
or hardware
store.
See also Clearance
Requirements
on the next page.
......
_-_ NOTE
......................
Use of 90 ° quick-turn
elbow
is required
to meet minimum
installation
depth of free-
standing
dryer.