7410F IFL Installation and Users Guide
9.7 Changing the Primary Power Setting
By default all Foxcom products are set operation at 230 VAC. To change to
115 VAC operation the instructions below must be followed to avoid
damage to both personnel and equipment.
To change the mode:
1. Disconnect the AC power.
2. Unplug the power supply module from the chassis.
3. Place a small screwdriver under the Lip.
4. Gently press upwards; the Fuse Drawer will come out slightly.
Figure 50 - Fuse Drawer
Figure 51 - Voltage Selector (230 Side)
5. Pull the Fuse Drawer out completely; the Voltage Selector is at the top of
the compartment. The number on the Voltage Selector is 230.
6. Using the screwdriver, gently remove the Voltage Selector from the
Connector.
7. Turn the Voltage Selector so that the number 115 facing outward.
Figure 52 - Voltage Selector (115 Side)