NORMAL CARE & MAINTENANCE INSTALLATION Front Grill and Filter Removal Complete step-by-step installation instructions are The front contains an air filter that can be removed on furnished with your unit. These instructions will be the left or right side of the front. To clean the filter use found on a separate page included with this manual the following method for filter removal: or in the mounting kit assembly.
Page 4
Fan Motor Care The fan motor is permanently lubricated for long life. There is no need to oil the motor. Slide-out Chassis Removal from Outer Case 1. Remove two side Phillips screws attaching case to chassis base-pan. 2. Remove two control knobs. 3.
INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before IMPORTANT: observe all governing codes and starting installation. ordinances. Read and follow the instructions provided with any tools listed here. Check the location where air conditioner will be installed.
Page 6
Window Installation Through-the-wall Installation Window opening measurements: The wall opening measurements should be: 27” min to 38” max (68.6 cm to 96.5 cm) Height: 15 9/16” (39.5cm) plus twice the opening width. thickness of wood used to build frame. ...
ELECTRIAL REQUIREMENTS This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances.
Page 8
NOTES: The Reset button must be pushed in for proper operation. The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset. Do not use the power supply cord as an off/on switch.
INSTALLATION INSTRUCTIONS UNPACKING 3. Remove front panel by removing 2 Phillips screws on both sides. 4. Remove both knobs from control panel. 5. Pull on handle to slide air conditioner out of cabinet. Place air conditioner on cardboard. Remove packaging materials. ...
Page 10
Attach side curtains Attach Foam Adhesive Seal Locate provided bag of screws Insert top and then bottom of right-hand curtain housing in top and bottom curtain guides on air conditioner cabinet. Back View Install Cabinet into Window Handle air conditioner gently. ...
Page 11
4. Use a 3/16” drill bit to drill 3 starter holes ½” 2. Insert one of the #10 x ¾” round-head deep through the 3 holes in the cabinet and screws through hole and into lower window into the window sill. sash.
Page 12
Secure the front grille to the case by replacing the Install the Air Conditioner in the Case Slide the air conditioner into the case by the base 2 screws removed earlier. pan. Do not push on the controls, styrofoam air Press on the top of the grille to help with side discharge housing or the finned coils.
THROUGH-THE-WALL INSTALLATION Through-the-wall Cabinet Installation Install Wood Frame 1. Construct wood frame. “Location Requirements” for dimensions. NOTES: 2. Measure outside width and height of frame to Handle air conditioner gently. determine wall opening dimensions. Be sure your air conditioner cabinet does not 3.
Page 14
Use a level to check that cabinet is level side to Insert air conditioner into cabinet. side. Install ground screws on both sides of cabinet. Insert front tabs of front panel into top of cabinet and swing front into place. Attach bottom front of panel with front panel screws.
GENERAL OPERATING INSTRUCTIONS While operation of all units is similar, controls vary slightly from model to model. Operating Controls section shows control panel of unit purchased and gives detailed information about operation of controls. Airflow Around Unit Changing airflow Direction Baffles Select the highest fan speed and set temperature Airflow on unit may be diverted left or right from control to its coldest position.
OPERATING CONTROLS Fan Control Temperature Control Completely shuts off the unit. To prevent Turn this control to the left for a warmer room blowing fuses, wait two minutes after turning the unit temperature, to the right for a cooler temperature. off before turning it on again.
TROUBLESHOOTING The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and suggested remedies are given for each problem. UNIT WILL NOT RUN NOISY UNIT Push reset button on power cord. Tighten any loose parts Set Fan control to position other than OFF.
WARRANTY International Refrigeration Products warrants that the product supplied is free from defects in material and workmanship. This warranty is valid as long as this product is properly handled, installed, operated and serviced in accordance with the Installation and Operating Instructions shipped with this unit, and the warranty card is completed and mailed no later than 30 days after date of purchase.