MSC49HP13115A 9H43YGX MS212A13115A 12A23YGX MSC412HP13115A 12H43YGX MS212A13240A 12A23ZGX FOR YOUR SAFETY AND EASE OF INSTALLATION PLEASE READ AND UNDERSTAND INSTRUCTIONS BEFORE STARTING. International Refrigeration Products, Inc. Technical Support (704) 504-8590 8 am to 4:30 pm Mon. – Fri. 950-0139 7/21/2009...
Parts List: 33 ft. Single Zone Installation Kit. CONTENTS PART NO. DESCRIPTION (1) 39 ft. 951-0405-1 Power Cable #12-3C Black, White, Green (1) 39 ft. 951-0405-2 Power Cable #12-4C Black, White, Red, Green (1) 33 ft. 951-0406-1 1/4" Copper Tubing, Insulated, W/Fittings (1) 33 ft.
condensation to drain away Heat pump models must be mounted with a minimum of 4” clearance to allow for drain connections. Plasti-Duct floor supports work well for this application. o The outdoor unit should be placed on a condenser pad. o If it’s a heat pump it must be raised up approximately 4'' to allow for connections and defrost to drain away.
Drill hole for connections: o Use a Phillips head screwdriver to remove the unit pipe strap. If the unit is a MSC49HP13115A, 9H43YGX, MSC412HP13115A or 12H43YGX heat pump the defrost sensor cable must be located. o If mounting the unit on an outside wall, measure from the edges of the unit to the center of the line set stub 90°...
Page 6
Bend stub out 90° Indoor unit: Condensate drain Wire fed from back Wire retaining clamp Indoor unit: Defrost cable location for MSC49HP13115A, 9H43YGX, MSC412HP13115A or 12H43YGX. Defrost cable not included with kit; it is included with the indoor unit. 950-0139 7/21/2009 - 6 -...
Outdoor unit: Remove top cover to expose defrost cable. Hanging Indoor Unit: o Once the bracket has been mounted and the power cable(s) fed through the 3” hole from the outside (assuming outside wall installation) gently bend the stub outward (90° to unit). o Feed the power cable through the back into the terminal compartment.
Torque Table Pipe Diameter Tightening Torque Inch ft-lb 25 to 30 11 to 15 36 to 42 Service valve Torque flare fitting Vacuum and Leak Test: o Attach gauges to the service ports. o Outdoor unit is factory pre-charged; make sure shut off valves are closed (as received) during pressure testing and evacuating.
Page 9
o Ground connection must be made to the terminal plate. o For easier access to the terminals in the outdoor unit remove the lower access panel to install whip and seal-tite connectors for conduit. o Access to outdoor terminal strip will vary by model. o Control wiring from the outdoor unit must be a point to point i.e.
Connecting the condensate drain line extension: o Connect the supplied drain line to the gray condensate line coming from the indoor unit. o The condensate line should be placed under the copper tubing in order to drain more efficiently. o After the copper tubing, wiring and condensate hose has been installed wrap the bundle with the 2”...
Check system operation: o The outdoor unit is pre-charged at the factory so no additional adjustment to refrigerant charge is required if line set is at design length or less. o Additional charge must be weighted in per the following table. Model Design oz.
Start up procedure: o Cool Mode: Press the On/Off button on the remote. An audible “BEEP” should be heard. The louvers should open and the indoor fan should start. o Press the mode button to set the mode to “COOL”. o Change the set point temperature to read “61º”.
Page 15
MINI-SPLIT REFRIGERANT FLOW (AIR ONLY) CONDENSER (OUTDOOR UNIT) COMPRESSOR/ACCUMULATOR EVAPORATOR (INDOOR UNIT) CONDENSER COIL EVAPORATOR EVAPORATOR COIL CAPILLARY DRIER FLARE COUPLING SHUT-OFF VALVE HIGH PRESSURE LOW PRESSURE SERVICE PORT (LOW PRESSURE) EXAMPLE PRESSURE 95 DEGREES OUTSIDE AMBIENT TEMPERATURE SHOULD READ APPROXIMATELY 143 PSI FOR R-410a AND APPROXIMATELY 82 PSI FOR R-22 SYSTEMS UNDER NORMAL OPERATION INDOR UNT SHOULD PROVIDE A TEMPERATURE DIFFERENTIAL OF APPROXIMATELY 20 DEGREES F.
Final Installation INDOOR UNIT TEMPERATURE DISPLAY AND IR RECEIVER AIR RETURN AIR OUTLET AIR FILTER UNDER COVER OUTDOOR UNIT LINE-SET AND CABLES CONDENSATE DRAIN Note: Line connection may vary by model Note: Line connection may vary by model. Typical installation shown, your model may vary.
If the unit exhibits a defect in normal use and is determined to be within the warranty period, International Refrigeration Products, Inc. will, at its option, either repair or replace the unit free of charge within a reasonable time after the unit is returned.