Kenmore 29 IN. (73.7CM) Installation Instructions Manual page 4

29 in. (73.7cm) electric dryer
Hide thumbs Also See for 29 IN. (73.7CM):

Advertisement

Available languages

Available languages

Power S upply Cord
Direct
W ire
Fire Hazard
Use a new UL approved
30 amp power supply
cord.
Use a UL approved
strain retief.
Disconnect
power before making emectrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver}.
Ground wire (green or bare wire} must be connected
to
green ground connector.
Connect remaining
2 suppmy wires to remaining
2 terminals
(gored).
Securemy tighten
aimelectricam connections.
Faimure to do so can reeumt in death, fire, or
electrical
shock.
1. Disconnect
power.
2. Remove the hold-down
screw and terminal block cover.
2
4
1
,!i
1. Terminal block cover
2. External ground connector
3. Center, silver-colored
terminal-block
screw
4. Hold-down
screw location
5. Neutral grounding
wire (green/yellow)
6. Hole below terminal block opening
Fire Hazard
Use 10 gauge somid copper
wire,
Use a UL approved
strain
relief.
Disconnect
power before making emectrical connections.
Connect neutram wire (white or center wire) to center
terminal
(simver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 suppmy wires to remaining
2 terminals
(gold).
Securety tighten
aime_ectrica{ connections.
Failure to do so can result in death, fire, or
electrica_ shock.
3. Assemble a % in. (1.9 cm) UL approved strain relief (UL
marking on strain relief) into the hole below the terminal block
opening. Tighten strain relief screws just enough to hold the
two clamp sections together. Put power supply cord through
the strain relief, The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position,
Now complete installation following instructions
for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)