Installation Manual For Indoor Unit
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with
less than 2% voltage drop.)
Phase Switch breaker
Item
For series 142 182
For series 242
(2) Wiring connection
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by
terminals.
AD142ALERA
AD182ALERA
AD242ALERA
AD242ALEAA
AD142ALEAA
AD182ALEAA
Circuit breaker
(A)
1
40
1
40
INDOOR UNIT
TERMINAL BLOCK
OUTDOOR UNIT
TERMINAL BLOCK
POWER SUPPLY:
1PH, 220-230V~, 50Hz
OUTDOOR UNIT
TERMINAL BLOCK
INDOOR UNIT
TERMINAL BLOCK
Overcurrent protector
rated capacity (A)
26
26
L
N
1
2
3
N
L
1
2
3
POWER SUPPLY:
1PH, 220-230V~, 50Hz
21
Earth leakage breaker
Power source
wire size
Switch
(minimum)
breaker
2
2.5mm
40A
2
4.0mm
40A
1
2
3
1
2
3
Leak
current
30mA
30mA