Haier 10506358 Installation Manual

Haier room air conditioner installation manual

Advertisement

Quick Links

Installation Manual of Room Air Conditioner

Preparation
Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
more than 5cm
more than
10cm
Arrangement of piping
directions
Rear left
Left
Below
The marks from
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.0010506358
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
corresponding name plate.
Rear
right
Right
more than 10cm
more than 10cm
to
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
Attention must be paid to
the rising up of drain hose
G
more than 10cm
F
A
C
D
more than15cm
Selection of Installation Place
lamps in the room are lightened.
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor fixing dimensions of the
outdoor unit (Unit:mm)
113.5
583
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
E
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.
113.5

Advertisement

loading

Summary of Contents for Haier 10506358

  • Page 1: Installation Manual Of Room Air Conditioner

    Please be subject to the actual product purchased , the above picture is just for your reference. Read this manual before installation Explain sufficiently the operating means to the user according to this manual NO.0010506358 Selection of Installation Place Indoor Unit ●...
  • Page 2: Indoor Unit

    Accessory parts Drain hose (1) Remote controller (1) Cushion (4) R-03 dry battery (2) Drain-elbow (1) Mounting plate (1) Plastic cap (4) Pipe supporting plate (1) Ø4X25 Screw (4) Selection of pipe Liquid pipe (Ø) Gas pipe (Ø) 12.7mm(1/2”) NOTE:The thickness of the pipe must be 0.8mm at least. Indoor unit Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed...
  • Page 3: Outdoor Unit

    If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by profes- sional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant.
  • Page 4 2-way valve 3-way valve CAUTION ● If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize first, then charge the liquid refrigerant into air conditio- ner according to the amount marked on the name plate.