Daikin FVXG25K2V1B Operation Manual page 39

Room air conditioner
Hide thumbs Also See for FVXG25K2V1B:
Table of Contents

Advertisement

CODE
00
U0
SYSTEM
U2
U4
A1
A5
A6
INDOOR
UNIT
A9
CE
C4
C9
EA
E1
E5
E6
E7
F3
H0
OUTDOOR
H6
UNIT
H8
H9
J3
J6
L4
L5
P4
NOTE
A short beep and two consecutive beeps indicate non-corresponding codes.
To cancel the code display, hold
Fault diagnosis by remote controller
The remote controller can receive from the indoor unit a corresponding error code according
to the fault.
1.
When
"
" indication blinks on the temperature
display section.
2.
Press
beep is produced.
The code indication changes as shown below, and notifi es with a long beep.
NORMAL
REFRIGERANT SHORTAGE
OVER-VOLTAGE DETECTION
SIGNAL TRANSMISSION ERROR (BETWEEN INDOOR AND OUTDOOR UNIT)
INDOOR UNIT PCB ABNORMALITY
HEATING PEAK-CUT CONTROL OR FREEZE-UP PROTECTION (PERCEPTIBILITY BY
THERMISTOR FOR INDOOR HEAT EXCHANGER)
FAN MOTOR (DC MOTOR) ABNORMALITY
RADIANT PANEL TEMPERATURE RISE OR MOTOR OPERATED VALVE ABNORMALITY
FREEZE-UP PROTECTION (PERCEPTIBILITY BY THERMISTOR FOR RADIANT PANEL)
RADIANT PANEL THERMISTOR ABNORMALITY
INDOOR HEAT EXCHANGER THERMISTOR ABNORMALITY
ROOM TEMPERATURE THERMISTOR ABNORMALITY
FOUR WAY VALVE ABNORMALITY
OUTDOOR UNIT PCB ABNORMALITY
OL ACTIVATION (COMPRESSOR OVERLOAD)
COMPRESSOR LOCK
DC FAN LOCK
DISCHARGE PIPE TEMPERATURE CONTROL
COMPRESSOR SYSTEM SENSOR ABNORMALITY
POSITION SENSOR ABNORMALITY
DC VOLTAGE / CURRENT SENSOR ABNORMALITY
OUTDOOR TEMPERATURE THERMISTOR ABNORMALITY
DISCHARGE PIPE THERMISTOR ABNORMALITY
OUTDOOR HEAT EXCHANGER THERMISTOR ABNORMALITY
RADIATION FIN TEMPERATURE RISE
OUTPUT OVERCURRENT DETECTION
RADIATION FIN THERMISTOR ABNORMALITY
for 5 seconds. The code display also cancel itself if the button is not pressed for 1 minute.
is held down for 5 seconds, a
repeatedly until a continuous
MEANING