Controller Operations; Manual Operation - Daikin EDHQ011BA6V3 Operation Manual

Unit for air to water heat pump system
Hide thumbs Also See for EDHQ011BA6V3:
Table of Contents

Advertisement

Controller operations

Manual operation

In manual operation, the user manually controls the settings of the
installation. The last setting remains active until the user changes it or
until the schedule timer forces another setting (refer to
timer operation" on page
7).
As the controller can be used for a wide variety of installations, it is
possible to select a function which is not available on your
installation. In that case the message
Switching on and setting space cooling (
1
Use the
=
button to select space cooling (
Icon
c
or
h
appears on the display as well as the corresponding
water temperature set point.
2
Use the
bi
and
bj
temperature.
Temperature range for heating: 25°C to 55°C
The temperature for heating can be set as low as 15°C (see
"Field settings" on page
heating should only be set lower than 25°C during
commissioning of the installation. When set lower than 25°C,
only the backup heater will operate.
In order to avoid overheating, space heating is not operable
when the outdoor ambient temperature rises above a certain
temperature (as set through field setting [4-02], refer to
settings" on page
11).
Temperature range for cooling: 5°C to 22°C
CAUTION
The actual operation range depends on the values set on
field setting [9].
These values shall be determined based on the
application.
NOTE
In heating mode (
can also be weather dependent (icon
This means that the controller calculates the water
temperature set point based on the outdoor temperature.
In this case, instead of showing the water temperature
set point, the controller shows the "shift value" which
can be set by the user. This shift value is the
temperature difference between the temperature set
point calculated by the controller and the real set point.
E.g. a positive shift value means that the real
temperature set point will be higher than the calculated
set point.
3
Switch on the unit by pushing the
The operation LED
0
lights up.
NOTE
When the unit is connected to an external room
thermostat, buttons
the icon
e
is shown. In this case, the external room
thermostat switches the unit on or off and determines
the operation mode (space cooling or space heating).
E(D/B)(H/L)Q011~016BA6V3+W1
Unit for air to water heat pump system
4PW57622-1
"Schedule
n
will appear.
c
) and heating (
c
) or space heating (
buttons to set the desired water
11). However, the temperature for
h
), the water temperature set point
a
is shown).
y
button.
=
and
y
are not operable and
Selection and setting of domestic water heating (
1
Use the
v
Icon
w
appears on the display.
2
Use the
temperature set point and subsequently, to set the correct
temperature.
The actual temperature set point only appears on the display
after pressing one of the buttons
pressed for 5 seconds, the temperature set point will
automatically disappear from the display again.
Temperature range for domestic water heating: 30°C to 78°C
h
)
3
Press the
v
h
).
Icon
w
disappears from the display.
Remark that pushing the
the domestic water heating. Domestic water heating is only
switched on or off by means of the
Selecting powerful domestic water heating operation
1
Press
v
heating operation.
Icons
w
and
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (
"Field
1
Use the
s
Icon
s
appears on the display.
If the controller is set in permission level 2 or 3 (refer to
settings" on page
Selecting weather dependent set point operation (only in
heating mode)
1
Press the
operation.
Icon
a
appears on the display as well as the shift value. The
shift value is not shown in case it is 0.
2
Use the
bi
Range for the shift value: –5°C to +5°C
Displaying actual temperatures
1
Push the
ba
The
b
icon and the outgoing water temperature are displayed.
The icons
2
Use the
pi
The outdoor temperature (
The domestic hot water tank temperature (
flashing).
The outgoing water temperature (
If no button is pressed for 5 seconds, the controller leaves the
display mode.
button to activate domestic water heating (
wi
or
wj
button to display the actual
wi
button to deactivate domestic water heating (
y
button has no influence on
v
for 5 seconds to activate powerful domestic water
m
start flashing.
s
)
button to activate quiet mode operation (
11), the
s
button will not be operable.
ba
button to select weather dependent set point
and
bj
buttons to set the shift value.
button for 5 seconds.
l
and
=
are flashing.
and
pj
buttons to display:
u
icon is flashing).
=
w
)
w
).
or
wj
. If no button is
w
).
button.
s
).
"Field
w
icon is
are flashing).
Operation manual
6

Advertisement

Table of Contents
loading

Table of Contents