2. The front panel should indicate Boot Loader Mode and show the time
3. The terminal screen will show the following message (note that the version
4. After typing "H" you will receive the following output.
5. Type "DLAPP A F" to download (force to flash A) the latest .DL applica-
6. On the terminal program, send the desired application (DTV701_nnn.DL)
wegener.com
d) When the red alarm LED goes on again, push the right arrow key.
e) The unit should now be in upload mode and accessible via the terminal.
remaining to initiate the upload. The front-panel warning and alarm LEDs
are flashing. If the download is not initiated within five minutes, the unit
automatically restarts and runs the current application.
Boot Loader Mode
Terminal Time: 04:54
may differ from that indicated below).
Entering Terminal Mode.
Mode will timeout after approx. 5 min. of inactivity.
Wegener Communications Copyright 2002
DTV700 Boot Loader Version 100
Type H for a list of terminal commands
>
SETBAUD baud_rate
DLAPP [A | B] [F]
GOAPP [F]
RESET
APPSTAT [Q]
SWITCH [A | B]
OK>
tion file to the DTV701. (To download to flash B, type "DLAPP B F".)
by entering send file using the XMODEM 1K protocol. (Only the
Set terminal rate (9600, 19200, 38400,
57600, 115200)
Download over bad app in flash (.DL file)
A | B Download to flash A or B (A is
default)
F
Force download even if app is good
Starts the current application ('F' forces
app. load)
Resets the unit
Reports application info. ('Q' performs
quick check)
Switches app A or B. If no arg, switch to
backup.
33
800015-01 Rev. D