Sharp MD-X5H Service Manual page 26

Hide thumbs Also See for MD-X5H:
Table of Contents

Advertisement

MD-X5H/CP-X5H
Setting Method
Step No.
Step 18
Press once the CD PLAY button. TCRS comparison level 1 for high reflection
Step 19
Press once the CD PLAY button. Comparison level in case of COUT generation (playback)
Step 20
Press once the CD PLAY button. Comparison level in case of COUT generation (pecord)
Step 21
Press once the CD PLAY button. Auto-move waiting time setting
: Setting volue
• Pressing the REC button causes reversing.
• If the VOL UP button is pressed while the specific setting item is indicated, the setting increases, and the new setting is set in LSI.
• If the VOL DOWN button is pressed while the specific setting item is indicated, the setting decreases, and the new setting is set in LSI.
• If the VOL UP/VOL DOWN button is held down, the setting changes continuously with 100 ms cycle.
d) Slide setting
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the CD PLAY button seven times. EEPROM setting menu
Step 3
Press once the MD PLAY button. Focus setting menu
Step 4
Press the CD PLAY button three times. Slide setting menu
Step 5
Press once the MD PLAY button. Slide system loop filter gain constant setting
Step 6
Press once the CD PLAY button. Slide system loop filter f characteristic constant 2 setting
Step 7
Press once the CD PLAY button. Slide output limitter setting
Step 8
Press once the CD PLAY button. Slide servo output dead zone level setting
Step 9
Press once the CD PLAY button. Slide kick pulse level setting (forced move)
Step 10
Press once the CD PLAY button. Slide kick pulse level setting (for 10 lines jump auxiliary use)
Step 11
Press once the CD PLAY button. Slide kick pulse level setting (move)
: Setting volue
• Pressing the REC button causes reversing.
• If the VOL UP button is pressed while the specific setting item is indicated, the setting increases, and the new setting is set in LSI.
• If the VOL DOWN button is pressed while the specific setting item is indicated, the setting decreases, and the new setting is set in LSI.
• If the VOL UP/VOL DOWN button is held down, the setting changes continuously with 100 ms cycle.
Temperature measurement value correction table
Ambient temperature
12.2 C ~ 15.8 C
15.9 C ~ 19.6 C
19.7 C ~ 23.2 C
23.2 C ~ 26.8 C
26.9 C ~ 30.7 C
30.8 C ~ 34.3 C
34.4 C ~ 37.9 C
• Temperature code check
The temperature code is read after automatic adjustment. If it is within the range shown below, the adjustment is OK.
Ambient temperature
19.6 C ~ 30.7 C
8.7 C ~ 19.6 C
correction
-0 3
H
-0 2
H
-0 1
H
0
H
+0 1
H
+0 2
H
+0 3
H
temperature code
0 6
0 7
– 26 –
Remarks
Remarks
EEPROM record value = Microcomputer measurement value +
Correction
*
EEPROM record value
Value to be measured by the microcomputer at +25 C
* Microcomputer measurement value
Value to be measured by the microcomputer at specific
temperature
* Correction value
Correction value for conversion to measurement value at
+25 C (see the table shown left)
Display
[ T C R S C 1 P _
]
[ C O T L V p _ _
]
[ C O T L V r _ _
]
[ W A I T m_ _ _
]
Display
[ t s m
e
]
[E E P R O M _ S E T]
[ _ _ F o c u s _ _ _ ]
[ _ _ _ S l e d _ _ _ ]
[ S L G _ _ _ _ _
]
[ S L 2 _ _ _ _ _
]
[ S L D L I M _ _
]
[ S L D L E V _ _
]
[ S L K L V k _ _
]
[ S L K L V t _ _
]
[ S L K L V m _ _
]