4.9 Input management parameters

The playing of the files takes place by activating the available logical inputs, the activation
modes are set through the IMOD, TPCM MICP and MIRS parameters inserted in the
configuration files.
Example:
IMOD=0
TPCM=10
MICP=1
MIRS=0
Mnemonic
Description of timing parameter
IMOD
Setting the mode of input active high or active low.
Setting the persistence time of the input command (time to wait before Panelplayer is
TPCM
able to interpret the input command) expressed in decimals of milliseconds (value
between 0 and 255 in decimal).
MICP
Setting Mode Input Continuous Play
MIRS
Setting Mode Input ReStart
IMOD (Input management mode)
0= active-low input mode; the functioning of the input is connected to the
ground/GND of the device.
IMOD
1= active-high input mode; the functioning of the input is applied with a positive
voltage between 5 and 12Vdc.
TPCM (Time persistence input command mode)
0 =no delay
TPCM
1 =10mSeconds
2 =20mSeconds
MICP (Mode Input Continuous Play)
0=having terminated the playing of the codified file, requested from the input
code, Panelplayer goes in standby.
MICP
1=the requested codified file is continuously played until the relevant input code
is inserted.
MIRS (Mode input Restart)
0=repeated activation or deactivating of the same input code does not
influence the playing of the relevant file. Only the activation of a different
code can block the playing underway and activate the playing of the new
MIRS
requested file.
1=in the moment in which an input code is enabled the playing of the of the
relevant file from its beginning takes place, even if it is already in play.
Panelplayer User Manual v.1.4
Page 15
100= 1 second
200= 2 seconds
250= 2,5 seconds

Advertisement