Setting Of The Dip Switches; Dip-Sw 1; Dip-Sw 2 - Star Micronics DP8340R Series User Manual

Serial interface
Hide thumbs Also See for DP8340R Series:
Table of Contents

Advertisement

8-3. Setting of the DIP Switches

8-3-1. DIP-SW 1

Switch
1-1
1-2
1-3
1-4
1-5
DtR MODe (1 BlOCk)
1-6
1-7
1-8
(*1)
Baud rate
SW1-1
150
OFF
300
OFF
600
OFF
1200
OFF
2400
ON
4800
ON
9600
ON

8-3-2. DIP-SW 2

Switch
International character set :
2-1
2-2
2-3(*2)
2-4
Note: DIP switches are only read by the
controller at power turn on.
DIP switch changes should be
made with power off, or after
changing switch setting, turn the
power off and on again.
ON
D ata transfer rate — see below (*1)
Stop bit 1
8 data bits
No parity
Odd parity
SW1-2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
U.S.a
always ON
2-color Ribbon
CR Invalid
OFF
Stop bit 2
X-ON/X-OFF MODe
7 data bits
Parity checked
even parity
(*2) DIP Switch 2-3 should
SW1-3
be set to ON when you
OFF
use a 2-color ribbon for
ON
2-color printing.
OFF
ON
It should be set to OFF
OFF
when a monochrome
ON
ribbon is used.
ON/OFF
OFF
FRaNCe
Monochrome Ribbon
CR Valid
Figure 8-3. Setting of DIP Switch
– 27 –
Factory
setting
ON
ON
ON
ON
ON
ON
ON
ON
Factory
setting
ON
ON
ON
ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp8340rmDp8340rd