Compact Refrigerators

Installation

Location

Cabinets represented in this manual are intended for indoor
use only. Be sure the location chosen has a floor strong enough
to support the total weight of the cabinet and contents.
Reinforce the floor as necessary to provide for maximum
loading.
The location should be selected so that power cords can be
connected without any extensions.
For the most efficient operation, be sure to provide good air
circulation inside and outside the cabinet. Avoid hot corners
and locations near stoves and ovens.

Inside Cabinet

Do not pack refrigerator so full that air cannot circulate.

Outside Cabinet

4400 Series equipment door and drawer models
These cabinets have Delfield's "front-breathing" design. They
may be installed flush against a wall or built into a counter
as required.
The louver at the floor level must be kept completely clear
of any obstructions. Proper operation of these models is
dependent on air being able to flow freely through the front
louver. The louver at the back of the cabinet is not necessary for
proper operation, but any air flow through it is beneficial.
Any restriction of the proper air flow outlined
above, total or partial, will void the warranty on
the cabinet.

Leveling

A level cabinet will perform better because the drain pan
will drain properly, the drawers or doors will line up with the
frames and the cabinet will not be subject to undue strain.
Never stand on the unit or its drawers! Doing so
may result in bodily injury. They are not designed
to hold the weight of a person and will collapse if
misused in this manner.

Stabilizing

All models are supplied standard on casters for your
convenience, for ease of cleaning underneath and for mobility.
The cabinet must be installed in a stable condition
with the front wheels locked. Locking the front
casters after installation is the owner's and
operator's responsibility.

Plumbing

Self-contained models are standard with a condensate
evaporator. If, for some reason, a cabinet does not have a
condensate evaporator, or the evaporator fails, the cabinets
drain must have an outlet to an appropriate drainage area
or container.
Moisture collecting from improper drainage can
create a slippery surface on the floor and a hazard
to employees. It is the owner's responsibility to
provide a container or outlet for drainage.

Electrical Connection

A 6' (1.8 m) long grounded supply cord and three-pronged
plug are provided with standard cabinets. Simply plug into
a three-pronged wall outlet for proper grounding of the
cabinet to begin operation. Do not use an adapter to connect
to a two-pronged outlet. The three-pronged outlet provides
a ground connection which must be used to prevent a shock
hazard.
The wall outlet must be checked by a qualified
electrician to be sure a proper ground is present
and that the outlet provides the correct voltage
and required amperage to match the rating plate.
Any power cord that is frayed or damaged should
be replaced. When disconnecting the cabinet from
the power source, do not pull on the cord. Firmly
grip the plug and remove from outlet.
The 5-15P plug shown below is used on the various 4400
Series models.
Refer to the amperage data list in SPECIFICATIONS, the serial
tag, your local code or the National Electrical Code to be
sure the cabinet is connected to the proper power source.
A protected circuit of the correct voltage and amperage
must be run for connection of the line cord, or permanent
connection to the cabinet.
Power Switch
Salad and Mega top 4460, 4464, and 4472 models are equipped
with a power disconnect switch located at the rear of the unit
just below the thermostat control knob. Switch must be in
the "on" position for the unit to operate.
The thermostat must be turned to OFF and the
cabinet disconnected from the power source
whenever performing service, maintenance
functions or cleaning the refrigerated area.