Compact Refrigerators

INSTALLATION

Location

Cabinets represented in this manual are intended for
indoor use only. Be sure the location chosen has a floor
strong enough to support the total weight of the cabinet
and contents. Reinforce the floor as necessary to provide
for maximum loading.
The location should be selected so that power cords can
be connected without any extensions.
For the most efficient operation, be sure to provide good
air circulation inside and outside the cabinet. Avoid hot
corners and locations near stoves and ovens.

Inside Cabinet

Do not pack refrigerator so full that air cannot
circulate.

Outside Cabinet

4400 Series equipment door and drawer models
These cabinets have Delfield's "front-breathing" design.
They may be installed flush against a wall or built into a
counter as required.
The louver at the floor level must be kept completely clear
of any obstructions. Proper operation of these models
is dependent on air being able to flow freely through
the front louver. The louver at the back of the cabinet
is not necessary for proper operation, but any air flow
through it is beneficial.
CAUTION
Any restriction of the proper air flow outlined above,
total or partial, will void the warranty on the cabinet.

Leveling

A level cabinet will perform better because the drain
pan will drain properly, the drawers or doors will line
up with the frames and the cabinet will not be subject
to undue strain.
CAUTION
Never stand on the unit or its drawers! Doing so may
result in bodily injury. They are not designed to hold
the weight of a person and will collapse if misused in
this manner.

Stabilizing

All models are supplied standard on casters for your
convenience, for ease of cleaning underneath and for
mobility.
CAUTION
The cabinet must be installed in a stable condition
with the front wheels locked. Locking the front
casters after installation is the owner's and operator's
responsibility.

Plumbing

Self-contained models are standard with a condensate
evaporator. If, for some reason, a cabinet does not have
a condensate evaporator, or the evaporator fails, the
cabinets drain must have an outlet to an appropriate
drainage area or container.
CAUTION
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owner's and operator's responsibility to provide
a container or outlet for drainage.

Electrical Connection

CAUTION
A 7' (2.1 m) long grounded supply cord and three-
pronged plug are provided with standard cabinets.
Simply plug into a three-pronged wall outlet for proper
grounding of the cabinet to begin operation. Do not
use an adapter to connect to a two-pronged outlet. The
three-pronged outlet provides a ground connection
which must be used to prevent a shock hazard.
CAUTION
The wall outlet must be checked by a qualified electrician
to be sure a proper ground is present and that the outlet
provides the correct voltage and required amperage to
match the rating plate.
Any power cord that is frayed or damaged should be
replaced. When disconnecting the cabinet from the power
source, do not pull on the cord. Firmly grip the plug and
remove from outlet.