Install the Optional Fan

If you are installing the optional convection Fan Kit
#2767 (FK26), continue here. If you are not installing a
Fan Kit, go to Page 15, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheo-
stat Assembly, connected by a cable. (Fig. 12) The
Blower Assembly mounts to the bottom rear of the
stove, and the Rheostat mounts to the valve cov-
erplate. The assembly includes a 'snapstat' which
automatically turns the fan On (or Off) above (or
below) approximately 109°. The Rheostat also pro-
vides a range of fan speed settings from Off (which
overrides the snapstat function) to High. Unpack and
inspect the Blower assembly. Confirm that the fan
spins freely.
WARNING
This appliance is equipped with a three-prong
(grounded) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
Not Used on RF
Models
Not Used
on
Oxford
Blower
Assembly
ST473
Fig. 12 Fan kit components.
2. Remove the rear skirt insert panel at the bottom of
ST473
the Rear Skirt (Fig. 13) and fasten the blower as-
Fan parts
sembly to the firebox back with the two Phillips pan-
#2767 FK26
head bolts originally installed in the firebox back. ('1',
9/29/00
Fig. 14)
3. Attach the snapstat assembly to the snapstat brack-
et with two sheet-metal screws. ('2', Fig. 14) Attach
the snapstat bracket to the stove with a hex-head
bolt passing through the bracket and into the stove
base. ('3', Fig. 14)
4. The rheostat control switch attaches to the left side
of the valve bracket at the front of the stove.
14
Snapstat
Bracket
Snapstat/
Extension
Assembly
Rheostat
Assembly
Not Used
on RF
Models
Connect to PC Board on
RF Models Only
Remove retaining nut from shaft of rheostat. (if
preinstalled)
Insert the rheostat through the hole in the back
of the left side of the valve bracket, aligning the
locator pin with the smaller hole in that bracket.
Thread the retaining nut onto the shaft of the
rheostat, tightening with a wrench. Do not over-
tighten.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat
wire harnesses together.
Rear Skirt
Sheet Metal
Screws
Rear Skirt Insert
Fig. 13 Remove rear skirt insert.
Star Washer
Sheet Metal Screws
2
Phillips
1
Pan
Head
Bolts
Star
Washer
Fig. 14 Attach the fan assembly and the snapstat.
ST314
Fk26ce
attach fan
1/24/00
Rheostat
Retaining Collar
Rheostat Knob
Fig. 15 Attach the fan rheostat.
ST757
ST1123
rear skirt insert
Snapstat
1/4" - 20
Hex Bolt
Snapstat
Bracket
3
ST314
ST758
Dutchwest
30005123
attach rheostat
5/15/03 djt