Vermont Castings Defiant FlexBurn Homeowner's Installation And Operating Manual page 8

Non-catalytic / catalytic woodburning stove
Table of Contents

Advertisement

Defiant
®
FlexBurn
1975 Non-Catalytic / Catalytic Woodburning Stove
Chimney
Elbow
Slip Pipe
Standard
Connector
Oval to
Round Adapter
Fig. 6 An exploded view of the chimney connection in a free-
standing masonry installation.
A special piece called the "thimble sleeve," slightly smaller
in diameter than standard connectors and most thimbles,
will facilitate the removal of the chimney connector system
for inspection and cleaning. (Fig. 7) Thimble sleeves are
available from your local dealer.
Thimble Sleeve
Chimney Connector
Fig. 7 The thimble, made of either ceramic or metal, must be
cemented securely in place.
To install a thimble sleeve, slide it into the breech until it is
flush with the inner flue wall. Do not extend it into the actual
flue passage, as this could interfere with the draft.
ST243
The thimble sleeve should protrude 1-2" (25-50 mm) into
thinble connection
12/13/99 djt
the room. Use furnace cement and thin gasketing to seal
the sleeve in place in the thimble. Secure the chimney
connector to the outer end of the sleeve with sheet metal
screws.
Without a thimble, a suitable length of chimney connector
can be extended through the breech to the inner face of
the flue liner, and cemented securely in place. Additional
pieces of connector are then attached with sheet metal
screws.
8
Flue
Flue In-
ner
Thimble
Flue Collar
ST492
Defiant
freestanding
installation
11/00
Flue
Keep
sleeve
end flush
with flue
tile
The chimney connector may be connected to the chimney
above the fireplace opening or through the fireplace.
The Defiant may be connected to a chimney above a
fireplace opening. (Fig. 8) In such installations, the stove
is positioned on the hearth in front of the fireplace and the
chimney connector rises from the stove top and then angles
ninety degrees back into the chimney. The chimney liner
should extend to the point at which the chimney connector
enters the chimney.
If the chimney connector in your installation enters the
chimney above a fireplace, follow all the guidelines men-
tioned above for freestanding installations. In addition, give
special consideration to the following points:
ST492
Check These
Clearances
Fig. 8 In this installation, the chimney connector attaches to the
chimney above the fireplace opening.
ST243
Check the clearance between the stove and the
chimney connector, and any combustible trim or the
mantel.
Check the clearance between the chimney connector
and the ceiling. The clearance should be at least 30"
(762 mm) with unshielded connectors. Consult the
clearance charts for other installation options.
The fireplace damper must be sealed to prevent room
air from escaping up the flue. However, it must be
possible to re-open the damper to inspect or clean the
chimney.
Fireplace installations
above the Fireplace
*
*
Mantel
Seal
D E F I A N T
This Off
ST244
Plymouth
fplc over mantel
12/99
ST244a
30005220