Section Iv - Operations Instructions; To Turn Off Gas To Appliance - Prestige Boiler User's Information Manual

Table of Contents

Advertisement

Operating Instructions
SECTION IV - OPERATING INSTRUCTIONS
WARNING
A
. This appliance does not have a pilot. It is
equipped with an ignition device which automat-
ically lights the burner. DO NOT try to light the
burner by hand.
B. BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air and
will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use
any phone in your building
• Immediately call your gas supplier from a
n e i g h b o r's phone. Follow the gas supplier's
i n s t r u c t i o n s .
1.
STOP! Read the safety information above on
this label. This appliance is equipped with an
ignition device which automatically lights the
burner. DO NOT try to light the burner by hand,
2.
Set room thermostat(s) to lowest setting. Turn the
external manual gas valve handle clockwise
"CLOSE" (valve handle shall be per-
pendicular to gas piping)
3.
Turn the service switch on the PRESTIGE con-
trol panel OFF.
4.
Remove the front jacket panel on the unit.
5.
Turn the external manual gas valve handle count-
er clockwise
(valve handle shall be parallel to gas piping).
6.
Wait five (5) minutes to clear out any gas. If you
then smell gas in the jacket enclosure or around
the unit, STOP! Follow "B" in the safety infor-
mation above. If you don't smell gas, go to the
next step.
1.
Set the room thermostat to lowest setting.
2.
Turn the service switch on the PRESTIGE con-
trol panel to "OFF"
FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
to "OPEN" gas supply

TO TURN OFF GAS TO APPLIANCE

• If you cannot reach your gas supplier, call the
fire department.
C. Use only your hand to turn the external manual gas
valve. Never use tools. If the valve will not turn by
hand, don't try to repair it; call a qualified service
technician. Force or attempted repair may result in
a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas control
which has been under water.
7.
Turn the service switch on the PRESTIGE con-
trol panel "ON".
8.
Set room thermostat(s) to desired setting(s).
9.
The PRESTIGE control panel display will show
a sequence of numbers (0,1,2,3,4,etc.) as the left
digit. Sequence digit 3 or 4 indicates the boiler is
firing. Sequence digit 0 means there is no call for
heat (all external thermostats are satisfied)
10. If the unit will not operate with a call for heat and the
system piping is not hot, follow the
" To Turn Off Gas to Appliance", below and call
your service technician or gas supplier.
11. Replace the front jacket panel. Make sure the panel is
seated firmly in place and all mounting screws are
t i g h t e n .
3. Turn the external manual gas valve handle clock-
wise
to "CLOSE".
7
i n s t r u c t i o n s

Advertisement

Table of Contents
loading

Table of Contents