1200
USER MANUAL
Compatible with low voltage multi-stage heat
pump systems with up to two stages of heating
and one stage of cooling. Not for use on
single-stage heating or cooling systems.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
CONTENTS
1

SPECIFICATIONS

2
INSTALLATION
3
TESTING YOUR NEW THERMOSTAT
4
PROGRAMMING USER SETTINGS
5
ADDITIONAL OPERATION FEATURES
6
TROUBLESHOOTING

WIRING DIAGRAMS

7
© 2004 Braeburn Systems LLC • Patents Pending • All Rights Reserved.
Builder Series
Non-Programmable
2 Heat / 1 Cool
Heat Pump Thermostat
Pub. No. 1200-100-006
WARNING!
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating
this thermostat.
• This thermostat is designed for use with a 24 Volt-AC low voltage multi-stage
heat pump systems.
• Do not use this thermostat on single stage systems or other systems with
voltages higher than 30 Volt-AC.
• This thermostat requires 24 Volt AC power for normal operation and control of
the heating or cooling system.
• Wiring must conform to all building codes and ordinances as required by local
and national code authorities having jurisdiction.
• Do not short (or jumper) across terminals at the heating or cooling system
control board to test the thermostat installation. This could damage the
thermostat and void the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F
(10˚ C). This could possibly damage the controlled cooling system and may
cause personal injury.
• This thermostat should only be used as described in this manual. Any other use
is not recommended and will void the warranty.
1
SPECIFICATIONS
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
3 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• Compatibility: Multi-stage heat pump systems with up to two stages of heating
and one stage of cooling.
• Terminations: R, C, G, Y, W2, E, O, and B
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1200 and is the answer not in the manual?

Questions and answers

Larry
April 7, 2025

In cool mode the room temperature does not reflect the actual temperature the room actual temperature is lower than what is shown

1 comments:
Mr. Anderson
April 7, 2025

The Braeburn 1200 may show a higher temperature than the actual room temperature in cool mode because the thermostat needs time to acclimate to the correct room temperature. This can happen if the thermostat was stored in a cold location before installation or if it was turned off during a cold period. Allowing the thermostat to warm up helps it display the correct temperature.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Braeburn 1200

  • Page 1: Specifications

    • Terminations: R, C, G, Y, W2, E, O, and B TESTING YOUR NEW THERMOSTAT PROGRAMMING USER SETTINGS ADDITIONAL OPERATION FEATURES TROUBLESHOOTING WIRING DIAGRAMS © 2004 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 1200-100-006...
  • Page 2: Replacing And Installing New Thermostat

    INSTALLATION INSTALLATION cont. Replacing Existing Thermostat Installing Your New Thermostat cont. 1. Always turn off power to the air conditioning or heating system prior to removing 10. Fasten the sub-base to wall using supplied screws. existing thermostat. 11. Connect wires to quick wiring terminal block as appropriate using the new terminal 2.
  • Page 3: Default Thermostat Settings

    PROGRAMMING PROGRAMMING USER SETTINGS USER SETTINGS cont. Default Thermostat Settings NOTE: Once you have finished setting the differentials, wait 5 seconds and the thermostat will return to the normal operating mode. Function Status After Reset Operation Mode Normal Operating Mode NOTE: To erase all user program settings, gently press RESET button using a paper Room Temperature...
  • Page 4: Resetting

    ADDITIONAL TROUBLESHOOTING OPERATION FEATURES cont. cont. Resetting The Thermostat SYMPTOM POTENTIAL SOLUTION The Reset feature allows the user to completely reset the thermostat and to register new Thermostat turns on Increase or decrease second (auxiliary) stage temperature manual ˚F / ˚C temperature scale switch settings. differential setting as appropriate to provide the desired second (auxiliary) 1.
  • Page 5: Wiring Diagram

    Heat terminals. Technical Assistance: www.braeburnonline.com 2. Make O / B connections as required by unit. Call us toll-free: 866-268-5599 (U.S. Only) 630-844-1968 (Outside the U.S.) © 2004 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 1200-100-006...

Table of Contents

Save PDF