REGENERATION FREQUENCY
To set the regeneration frequency, push the number of pins in
which corresponds to the number located in Table 2 (refer to
Fig. 9 and Table 3).
FIG. 9
TABLE 3 — RECHARGE FREQUENCY
No. Down on
Pin No. In on
Salt Chart
Frequency Dial
1
2
1 & 4
3
1, 3 & 5
6
All Pins
TABLE 4A — ESTATE
SALT
0-10
DOSAGE
(0-170)
1200
4
(270)
1300
5
(230)
1400
6
(200)
1400
7
(250)
1500
8
(210)
1500
9
(270)
1500
10
(270)
1600
11
(260)
1700
12
(200)
Recharge
Frequency
1
Every six days
Every three days
Every other day
Every day
2M 0.7FT
3
®
TOTAL WATER HARDNESS IN GRAINS PER GALLON (mg/l)
11-20
21-30
(171-340)
(341-515)
500
300
(235)
(190)
500
300
(265)
(210)
600
300
(200)
(233)
600
400
(225)
(150)
600
400
(255)
(170)
700
400
(185)
(190)
700
400
(210)
(207)
700
500
(230)
(120)
800
500
(150)
(133)
SOFT-MINDER METERING DEVICE
The Estate 2M water conditioners are equipped with a Soft-
Minder meter which regenerates based upon the water
consumption patterns of the household.
GALLONS SETTING
Determine the daily use for the household. Usually 75-100
gallons per day per person is adequate. Using Table 4, locate
the hardness range for your water supply. Move down the
column and locate the gallons setting and salt dosage which
best suits the application. Usually two to three days between
regenerations yields the best results. Allow for one half to
one days water usage as reserve capacity. Set the salt dosage
per the instructions on page 9.
Set the gallons setting on the circuit board. This is done by
removing the two screws of the front cover. The circuit board
is located on the upper left hand corner of the back plate. A
set of six dip switches on the circuit board determine the
gallons capacity. Refer to Table 5, Figs. 10 and 11 when
setting the dip switches. Make sure all recharge frequency
pins are pushed IN.
There are two pilot lights located on the circuit board.
• The green pilot light flickers when water is flowing through
the water meter.
• The amber pilot light is a latching indicator, when the pre
set gallon count has passed, the amber light will illuminate
indicating that the unit will regenerate that night.
GALLON CAPACITIES TO SIGNAL (RESERVE)
31-40
(516-685)
200
(168)
200
(183)
200
(200)
200
(213)
300
(128)
300
(143)
300
(155)
300
(165)
300
(175)
41-50
51-60
(686-855)
(856-1025)
NA
NA
200
NA
(106)
200
NA
(120)
200
NA
(130)
200
NA
(142)
200
NA
(154)
200
NA
(164)
200
200
(172)
(110)
200
200
(180)
(117)
61-75
(1026-1280)
NA
NA
NA
NA
NA
NA
NA
NA
NA
/ 11
SETTINGS

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Estate 2