Barnstead F46110CM Operation Manual

High temperature muffle furnace
Hide thumbs Also See for F46110CM:

Advertisement

High Temperature
F46110CM
F46110CM-33
F46118CM
F46120CM
F46120CM-33
F46128CM
F46120CM-75
F46120CM-33-75
F46128CM-75
LT1078X2 • 5/9/97
B
ARNSTEAD
Muffle Furnace
OPERATION MANUAL
AND PARTS LIST
Model Numbers
F46230CM
F46230CM-33
F46238CM
F46240CM
F46240CM-33
F46248CM
F46240CM-75
F46240CM-33-75
F46248CM-75
|T
C
HERMOLYNE
ORPORATION
Automatic
Automatic
Automatic
Multi-Programmable
Multi-Programmable
Multi-Programmable
Multi-Programmable
Multi-Programmable
Multi-Programmable
1

Advertisement

Table of Contents
loading

Summary of Contents for Barnstead F46110CM

  • Page 1 ARNSTEAD HERMOLYNE ORPORATION High Temperature Muffle Furnace OPERATION MANUAL AND PARTS LIST Model Numbers F46110CM F46230CM Automatic F46110CM-33 F46230CM-33 Automatic F46118CM F46238CM Automatic F46120CM F46240CM Multi-Programmable F46120CM-33 F46240CM-33 Multi-Programmable F46128CM F46248CM Multi-Programmable F46120CM-75 F46240CM-75 Multi-Programmable F46120CM-33-75 F46240CM-33-75 Multi-Programmable F46128CM-75 F46248CM-75 Multi-Programmable LT1078X2 •...
  • Page 2: Table Of Contents

    Table of Contents IMPORTANT INFORMATION This manual contains important operating and safety information. The user must carefully read and understand the contents of this manual prior to the use of this equipment. Table of Contents Safety Information ............................4 Alert Boxes ..............................4 Warnings ................................
  • Page 3 ABLE OF ONTENTS Furnace Loading: ............................29 Furnace Atmospheres ..........................30 Preventive Maintenance ..........................31 General Cleaning Instructions ....................... 32 Problem Solving Guide ..........................33 Maintenance and Servicing ..........................34 Wiring Diagram ............................38 Wiring Diagram ............................. 39 Wiring Diagram ............................. 40 Wiring Diagram ............................. 41 Replacement Parts List ..........................
  • Page 4: Safety Information

    Safety Information Safety Information Your Thermolyne furnace has been designed with function, reliability, and safety in mind. It is the user’s responsibility to install it in conformance with local electrical codes. For safe operation, please pay attention to the alert boxes through- out the manual.
  • Page 5: Warnings

    AFETY NFORMATION WARNING To avoid electrical shock, this furnace must: 1. Be installed by a competent, qualified electrician who insures compatibility among furnace specifications, electrical source and grounding code requirements. 2. Always be disconnected from the electrical supply prior to maintenance and servicing. To avoid personal injury: 1.
  • Page 6 Material Safety Data Sheets (MSDS) fo information regarding proper handling and recom- mended protective equipment. For additional MSDS copies, or additional information concerning the handling of refractory ceramic products, please contact the Customer Service Department at Barnstead|Thermolyne Corporation at 1-800-553-0039.
  • Page 7: Description

    Description Intended Use Types 461 and 462 are general purpose laboratory furnaces intended for applications requiring temperatures from 800-1700 degrees C. NOTE General Usage The fans operate continuously, even Do not use this product for anything other than its when the circuit breaker is OFF, to assure intended usage.
  • Page 8: Types Of Controllers

    ESCRIPTION The control section consists of a temperature controller, a current controller, a transformer, a contactor (relay), a circuit breaker, and a pilot light. The temperature controller senses the furnace temperature (by means of the thermocouple) and adjusts electricity to the heating elements by means of the current controller.
  • Page 9: General Specifications

    General Specifications General Specifications Model# F46110CM, F46118 F46120CM F46128 F46120CM-75 F46128CM-75 F46110CM-33 F46120CM,-33 F46120CM-33-75 Dimensions Overall-in Width 28-1/8 28-1/8 28-1/8 28-1/8 28-1/8 28-1/8 (cm) (71.4) (71.4) (71.4) (71.4) (71.4) (71.4) Height 18-1/2 18-1/2 18-1/2 18-1/2 18-1/2 18-1/2 (47) (47) (47)
  • Page 10: General Specifications

    ENERAL PECIFICATIONS Model# F46230CM, F46238 F46240CM F46248 F46240CM-75 F46248CM-75 F46230CM-33 F46240CM,-33 F46240CM-33-75 Dimensions Overall-in Width 34-1/8 34-1/8 34-1/8 34-1/8 34-1/8 34-1/8 (cm) (86.7) (86.7) (86.7) (86.7) (86.7) (86.7) Height 22-1/2 22-1/2 22-1/2 22-1/2 22-1/2 22-1/2 (57.2) (57.2) (57.2) (57.2) (57.2) (57.2) Depth (58.4)
  • Page 11: Declaration Of Conformity

    Declaration of Conformity Declaration of Conformity (-33 models only) Barnstead|Thermolyne hereby declares under its sole responsibility that this product conforms with the techni- cal requirements of the following standards: EMC: EN 50081-1 Generic Emission Standard; NOTE EN 50082-1 Generic Immunity Standard;...
  • Page 12: Unpacking

    Unpacking Unpacking Visually check for any physical damage to the shipping container. Inspect the equipment surfaces that are adjacent to any damaged area. Open the furnace door and remove packing material from inside the furnace chamber. Vacuum the chamber prior to use to remove the insulation dust due to shipment.
  • Page 13: Installation

    The electrical specifications are located on the specifica- tion plate on the back of the furnace. Consult Barnstead/ Thermolyne if your electrical service is different than those listed on the specification plate. Prior to connecting your Type 46100 or 46200 furnace to your electrical supply, be sure the front circuit breaker is in the OFF position.
  • Page 14: General Operation Of Furnace

    General Operation of Furnace General Operation of Furnace Observe these Warnings before operating your furnace: WARNING To avoid electrical shock, this furnace must: CAUTION 1. Be installed by a competent, qualified electrician who Remember that when the power switch insures compatibility among furnace specifications, electri- is turned “ON”, the furnace will begin to cal source and grounding code requirements.
  • Page 15: Circuit Breaker

    ENERAL PERATION OF URNACE Circuit Breaker A double pole circuit breaker is located at the bottom of the control section. It serves to turn electricity ON and OFF and to protect the electrical circuit. Fans The fans, located in the rear of the heating section and the control section, will run continuously as long as electricity is supplied to the furnace, even when the furnace panel circuit breaker is OFF.
  • Page 16: Operation Of Automatic Models

    Operation of Automatic Controls Operation of Automatic Models (Models F46110CM, F46110CM-33, F46118CM, F46230CM, F46230CM-33, F46238CM) Control Parameters PR = program ramp rate, the rate of heat increase or decrease in °C/minute. Pushing the up or down button will NOTE give the current setting of this ramp. Push up or down Thermolyne recommends that you set button to set.
  • Page 17: Tuning Your Furnace

    Rate for more information on ramping to setpoint. Sbr = the power that is required to indicate an open thermocouple condition exists. Push up or down button, if 0.0 is not displayed, contact Barnstead/Thermolyne. CAUTION Tuning Your Furnace Minimize operation of furnace under 800°C.
  • Page 18: Single Set Point Operation

    PERATION OF UTOMATIC ONTROLS 3. To stop tuning function, scroll until SAT is displayed and simultaneously push up and down buttons. Single Set Point Operation The automatic control is used as a single set point control, which includes one ramp to set point capability. To use as a single set point control, simply push up or down buttons to choose a specific temperature.
  • Page 19: Program Ramp Rate

    PERATION OF UTOMATIC ONTROLS Program Ramp Rate If you desire to ramp to the set temperature at a specified rate, depress scroll button until “PR” appears. (“PR” = program ramp rate, which is the rate of heat increase or decrease in °C/minutes). Depress up or down button to give current setting of ramp rate.
  • Page 20: Operation Of Programmable Models

    Operation of Programmable Models Operation of Programmable Models (F46120CM, F46120CM-33, F46120CM-33-75, F46120CM- 75, F46128CM, F46128CM-75, F46240CM, F46240CM-33, F46240CM-33- 75, F46240CM-75, NOTE F46248CM, F46248-75) Once the desired parameter has been selected, depressing either the raise or lower button will cause the param- Control Parameters eter to be replaced with the new value.
  • Page 21 Barnstead/Thermolyne. Sbr = the percent of power that is supplied to the control output terminals if an open thermocouple condition exists. Push up or down button. This parameter cannot be changed, if 0.0 is not displayed, contact Barnstead/ Thermolyne.
  • Page 22: Tuning Your Furnace

    PERATION OF ROGRAMMABLE ODELS Tuning Your Furnace The SAT Self and Adaptive Tuning feature starts the controller in the Self Tune mode, then automatically switches over to the Adaptive Tuning mode. Self Tuning is a one-time function which permits the user to tune the instrument control parameters to suit new process condi- tions.
  • Page 23: Operating The Controller

    PERATION OF ROGRAMMABLE ODELS Operating the Controller The programmable control can be used as a single CAUTION setpoint control or as a programmable control. Minimize operation of furnace under 800°C. Element life is reduced when operating below 800°C because the protective layer of silica glass takes longer to form.
  • Page 24: Multi-Programmable Controller Program Entry (Models F46120Cm, F46120Cm-33, F46120Cm-33-75, F46120Cm-75, F46128Cm, F46128Cm-75, F46240Cm, F46240Cm-33, F46240Cm-33-75, F46240Cm-75, F46248Cm, F46248Cm-75)

    PERATION OF ROGRAMMABLE ODELS desired ramp rate (PR). Dwell segments (PD) can be attached to each program level (PL) to hold that tempera- ture for a specified number of minutes. Multi-Programmable Controller Program Entry (Models F46120CM, F46120CM-33, F46120CM-33-75, F46120CM-75, F46128CM, F46128CM-75, F46240CM, F46240CM-33, F46240CM-33-75, F46240CM-75, F46248CM, F46248CM-75) The multi-programmable controller in the F46120CM-75,...
  • Page 25: Program Entry (All Models)

    PERATION OF ROGRAMMABLE ODELS Program Entry (all models) Set Ramp Rates 1. With the controller not operating, indicated by the bottom right hand side of the display extinguished, depress scroll button until PR1 is displayed. Push the up or down button to scroll to the desired value, which is degrees per minute.
  • Page 26 PERATION OF ROGRAMMABLE ODELS All other dwells in the program can be set in a similar fashion by selecting “PD” followed by the relevant dwell number. Set the Number of Times to Repeat the Program 4. Scrolling through the main scroll until the parameter “PLC”...
  • Page 27: Implementing Programs

    Implementing Programs Implementing Programs Program Execution Once the program has been entered it can be set running by depressing the ‘RUN/HOLD’ push button on the front. With the run initiated, the program will commence and the legend on the display will indicate if a ramp or dwell is being performed.
  • Page 28: Program Reset

    MPLEMENTING ROGRAMS segment type and will be flashing. Pushing “RUN/HOLD” button again will return the program to a run situation and extinguish the “HOLD” legend. Program Reset A running, held or finished program can be reset by de- pressing the up and down push buttons together. When the reset has been enabled, the parts of the display associated with programming will be extinguished and the controller will operate as a single setpoint control.
  • Page 29: Furnace Loading

    Furnace Loading Furnace Loading: Be sure to use care in loading and unloading the furnace chamber. Molybdenum disilicide heating elements are extremely fragile and can crack or break with just a slight bump. Be sure not to block the flow of radiant heat from the heating elements to the thermocouple.
  • Page 30: Furnace Atmospheres

    URNACE OADING Furnace Atmospheres This furnace is designed to be used to 1700°C in pure air only. It may be used with nitrogen, argon, or helium atmospheres to 1600°C. Reducing atmospheres are not recommended. The heating elements in this furnace are attacked by fluorine, chlorine, sodium and potassium compounds and also by molten metals.
  • Page 31: Preventive Maintenance

    Refer to the appropriate Material Safety Data Sheets (MSDS) for information regarding proper handling and recommended protective equipment. For additional MSDS copies, or additional information concerning the handling of refractory ceramic products, please contact the Customer Service Department at Barnstead|Thermolyne Corporation at 1-800-553-0039. WARNING To avoid electrical shock, this furnace must always be disconnected from the electrical supply prior to maintenance and servicing.
  • Page 32: General Cleaning Instructions

    REVENTIVE AINTENANCE General Cleaning Instructions Wipe exterior surfaces with lightly dampened cloth contain- ing mild soap solution. A few simple procedures will help insure that your furnace will give you long service. 1. Keep the chamber clean; this furnace is capable of achieving temperatures which will cause vaporization of many materials.
  • Page 33: Problem Solving Guide

    The following pages are intended to help you resolve functional problems with your furnace. Thermolyne is always available to assist you with problems. If this guide does not direct you to your specific problem, call or write Barnstead/Thermolyne at (1-800-553-0039). PROBLEM...
  • Page 34: Maintenance And Servicing

    Refer to the appropriate Material Safety Data Sheets (MSDS) for information regarding proper handling and recommended protective equipment. For additional MSDS copies, or additional information concerning the handling of refractory ceramic products, please contact the Customer Service Department at Barnstead|Thermolyne Corporation at 1-800-553-0039. CAUTION To avoid breakage of a replacement heating...
  • Page 35 AINTENANCE AND ERVICING To avoid premature burnout of a replacement heating element, be sure that the insulation tail supplied with the replacement element is inserted between the two legs of the element as shown in the drawing. Also be sure that the heating element projects sufficiently into the cham- ber.
  • Page 36 AINTENANCE AND ERVICING the heating element until the element ceramic holder rests on top the main insulation. Check the heating element on the inside of the chamber. The large diameter section of the element must be flush with or slightly projecting from the surface of the insulation (if not, reposition element ceramic holder).
  • Page 37 Figure 1A Element Replacement...
  • Page 38: Wiring Diagram

    Wiring Diagram Wiring DiagramWiring Diagram F46110CM, F46118CM, F46120CM, F46128CM, F46120CM-75, F46128CM-75...
  • Page 39: Wiring Diagram

    IRING IAGRAM Wiring DiagramWiring Diagram F46110CM-33, F46120CM-33, F46120CM-33-75...
  • Page 40: Wiring Diagram

    IRING IAGRAM Wiring Diagram Wiring Diagram F46230CM, F46238CM, F46240CM, F46248CM, F46240CM-75, F46248CM-75...
  • Page 41: Wiring Diagram

    IRING IAGRAM Wiring Diagram Wiring Diagram F46230CM-33, F46240CM-33, F46240CM-33-75...
  • Page 42: Replacement Parts List

    F46238CM) Temperature Control Programmable CN71X59 CN71X59 (8 ramp and 8 dwell 4 program) (F46120CM, (F46240CM, F46120CM-33, F46240CM-33, F46128CM) F46248CM) Thermocouple TCX5 TCX5 Thermocouple terminal block TRX137 TRX137 Transformer TNX79 TNX80 NOTE: Service on control units - contact Barnstead/Thermolyne Corp (1-800-553-0039).
  • Page 43: Ordering Procedures

    All parts listed herein may be ordered from the Barnstead|Thermolyne dealer from whom you purchased this unit or can be obtained promptly from the factory. When service or replacement parts are needed we ask that you check first with your dealer.
  • Page 44: Material Safety Data Sheet

    Material Safety Data Sheet Thermal Ceramics Material Safety Data Sheet Date Revised: 7/2/91 PRODUCT IDENTIFICATION Trade Name(s): CERAFIBER Generic Name: REFRACTORY CERAMIC FIBER INSULATION CAS #: 65997-17-3 Chemical Name: ALUMINA SILICA Formula: MIXTURE Manufacturer: Thermal Ceramics Telephone: (404) 796-4200 Address: P.0.
  • Page 45 ATERIAL AFETY HEET MAY BE AGGRAVATED. Target Organ(s): LUNGS, SKIN AND EYES . Acute Health Effects: PRODUCT IS A MECHANICAL IRRITANT TO SKIN, EYES AND UPPER RESPIRATORY SYSTEM. Chronic Health Effects: EXCESSIVE EXPOSURE TO RCF DUSTS AND AFTER SERVICE FIBERS MAY CAUSE LUNG DAMAGE (FI- BROSIS).
  • Page 46 ATERIAL AFETY HEET SPECIAL PRECAUTIONS *** ALWAYS SEGREGATE MATERIALS BY MAJOR HAZARD CLASS *** THIS PRODUCT CONTAINS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER. Storage Segregation Hazard Classes: IRRITANT Special Handling/Storage: KEEP MATERIAL DRY. Special Workplace Engineering Controls: ADEQUATE VENTILATION TO KEEP DUST LEVEL TO BELOW PEL/TLV/WEG (WORKPLACE EXPOSURE GUIDELINE).
  • Page 47: Warranty

    (1) year, the parts necessary to remedy any such defect. The warranty period shall commence either six (6) months following the date the product is sold by Barnstead|Thermolyne or on the date it is purchased by the original retail consumer, whichever date occurs first.
  • Page 48 Barnstead Thermolyne a subsidiary of 2555 Kerper Blvd. 9001 P.O. Box 797 Dubuque, IA 52004-0797 USA REGISTERED PHONE: 319-556-2241 • 800-553-0039 FAX: 319-556-0695 Web Address: http://www.barnsteadthermolyne.com...