Log Select 4Ch - Sony SDX-900V Product Specifications

5.25” model ait-4 drive
Hide thumbs Also See for SDX-900V:
Table of Contents

Advertisement

LOG SELECT

6.5. LOG SELECT 4Ch

Bit
7
Byte
0
1
2
PC
3
4
5
6
7
(MSB)
8
9
The LOG SELECT command provides a means for the Host to manage statistical information maintained by the
device about its own hardware or the installed media. This description should be read in conjunction with the
description of the LOG SENSE command which follows it, to provide the reader with information about log page
format, parameters and supported pages.
PCR: A Parameter Code Reset bit of one and a Parameter List Length of ZERO will cause ALL log pages which can
be cleared, to be cleared. If this field is set and the Parameter List Length field is non-ZERO then the command will
be terminated with a CHECK CONDITION status with the sense key set to ILLEGAL REQUEST, and an additional
sense code of INVALID FIELD IN CDB.
SP: The device does not have non-volatile RAM into which it may save parameters. Therefore, the Save Page bit is
not supported by this device and shall always be set to ZERO. If the SP bit is set, the command will be terminated
with CHECK CONDITION status with the sense key set to ILLEGAL REQUEST, and an additional sense code of
INVALID FIELD IN CDB.
PC: The Page Control field defines the type of parameter values to be selected:
If this field is set to 00b, 10b or 11b and the Parameter List Length field is non-0 then the command will be terminated
with a CHECK CONDITION status with the sense key set to ILLEGAL REQUEST, and an additional sense code of
INVALID FIELD IN CDB. This is because no modification of these log pages is permitted. For a description of
command behavior if this field is set to 01b then see the description of the Parameter List Length field below.
If this field is set to 10b and the Parameter List length field is 0 then all Current Threshold Values will be reset to the
Default Threshold Values. This is equivalent to no change as Threshold Values cannot be modified.
If this field is set to 11b and the Parameter List Length field is 0 then all Current Cumulative Values will be reset to the
Default Cumulative Values. This is equivalent to all log pages which can be cleared.
Parameter List Length: This field specifies the length in bytes of the LOG SELECT parameter list that shall be
transferred from the initiator to the target during the DATA OUT phase. A parameter list length of ZERO indicates
that no data shall be transferred. This condition shall not be considered as an error (see description of Parameter
Code Reset and Page Control fields above). If this field is non-0 the Page Control field must be 01b.
SONY AIT-4 drive SDX-900V series Ver.2.1
6
5
Operation Code (4Ch)
Obsolete
Parameter List Length
Table 6-5: Page Control field values
Value
00b
Current Threshold Values
01b
Current Cumulative Values
10b
Default Threshold Values
11b
Default Cumulative Values
4
3
2
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Control
Description
6.Command Specification
1
0
PCR
SP (0)
(LSB)
6-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdx-900v/r

Table of Contents