Safety; Conditions Of Acceptability; Installation Requirements; Power Requirements - Sony SDX-900V Product Specifications

5.25” model ait-4 drive
Hide thumbs Also See for SDX-900V:
Table of Contents

Advertisement

2.4. Safety

The SDX-900V conforms to the following safety standards:
• UL/cUL (Underwriters Laboratories, Inc.)
UL 60950 3rd Edition/CSA C22.2 No. 60950-00
Safety of Information Technology Equipment.
• TUV
IEC 950 Safety of Information Technology Equipment including
Electrical Business Equipment (First Edition)
• CE Mark

Conditions of Acceptability

2.4.1.
The SDX-900V is for use only in equipment where the suitability of the combination has been determined by an
appropriate certification organization (for example, Underwriters Laboratories, Inc. or the Canadian Standards
Association in North America, and the British Standards Institution or Verband Deutscher Elektrotechniker in
Europe). Other considerations include the following:
An enclosure must be supplied to limit the operator's access to live parts, to provide system stability, and to
1.
furnish the drive with the necessary grounding integrity.
The necessary voltage supplies must be provided. These supplies are Extra Low Voltage SEC for UL and
2.
CSA, or Safety Extra Low Voltage for BSI, VDE, and so on, of +5V and +12V DC.

2.5. Installation Requirements

Note: Do not move the drive while it is operating. It may cause malfunction.

Power Requirements

2.5.1.
Voltage
5V ± 5%
12V ± 10%
Note: Voltage has to increase constantly during Power-up until Maximum is reached.
Do not turn off the drive while the tape is in the drive.
SONY AIT-4 drive SDX-900V series Ver.2.1
Max Ripple
100 mV p-p
150 mV p-p
4.75V
T
0V
0V
-300 ms < T < 300 ms
Figure 2-5: Power-up Sequence
Current
Typical
1.5A
0.75A
* exclude SCSI terminator power
5V
12V
10.8V
2.Specification
Maximum
2.5A
3.0A
2-9