Mode Sense (6/10) 1Ah And 5Ah - Sony SDX-900V Product Specifications

5.25” model ait-4 drive
Hide thumbs Also See for SDX-900V:
Table of Contents

Advertisement

6.Command Specification

6.8. MODE SENSE (6/10) 1Ah and 5Ah

7
0
1
2
PCF
3
4
5
Vendor Specific (00b)
7
0
1
2
PCF
3-6
7-8
5
Vendor Specific (00b)
The MODE SENSE (6/10) commands provide a means to report its default, current and changeable configuration
parameters. They are complementary to MODE SELECT (6/10) commands. The 6-byte and 10-byte commands can
be interchanged.
The format of the data returned is different for the six and ten byte commands. See the MODE SELECT (6/10)
commands for the mode header format differences.
LLBAA: The LLBAA function is not supported. This field must be ZERO. This field is defined for MODE SENSE 10
only.
If this field is not set to 0b for a MODE SENSE (10) command, the command terminates with CHECK CONDITION
status, the sense key set to ILLEGAL REQUEST, the ASC/ASCQ is set to INVALID FIELD IN CDB.
DBD: A Disable Block Descriptors (DBD) bit of ZERO indicates that the target may return ZERO or more block
descriptors in the returned MODE SENSE data at the target's discretion. A DBD bit of one specifies that the target
shall not return any block descriptors in the returned MODE SENSE data.
PC: The Page Control field indicates the type of page parameter values to be returned to the Host as shown below.
Bit 7
Bit 6
Parameter Values
0
0
Current Values
0
1
Changeable Values
1
0
Default Values
1
1
Saved Values
The addition page length field of each page returned by the drive indicates the number of bytes supported for that
page. Fields not supported by the drive are set to ZERO.
Page Code: This allows the Host to select any specific or all pages supported by the drive. The page codes that are
supported are:
6-56
Table 6-49: Mode Sense (6) CDB Format
6
5
Operation Code (1Ah)
Reserved
Reserved
Table 6-50: Mode Sense (10) CDB Format
6
5
Operation Code (5Ah)
Reserved
LLBAA (0)
Reserved
Table 6-51: Page Control field values
Description
This is the normal default situation where the drive returns to the host
its current configuration. Page fields not supported are set to ZERO by
the drive.
These are any values which a host may alter in a subsequent MODE
SELECT command. Any field that the drive allows to be changed is set
to one. Otherwise the field is set to ZERO.
These are the default values on power-up
Not supported by the drive
4
3
DBD
Page Code
Reserved
Allocation Length
NACA (0)
4
3
DBD
Page Code
Reserved
Allocation Length
NACA (0)
SONY AIT-4 drive SDX-900V series Ver.2.1
MODE SENSE
2
1
0
Reserved
Flag (0)
Link (0)
2
1
0
Reserved
Flag (0)
Link (0)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdx-900v/r

Table of Contents