ELECRAFT KX3 Owner's Manual page 36

Ultra-portable 160-6 meter, all-mode transceiver
Table of Contents

Advertisement

AGC SPD
SLO
AGC*THR
007
ALARM
OFF
AM MODE
ON
ATU MD
Not Inst
AUTO INF
NOR
AUTO OFF
INFINITE
BAT CHG
Not Inst
BAT MIN
10.0
BKLIGHT
ON
This setting is stored per-mode. The default for CW mode is
modes,
. The setting is indicated by the
SLO
This menu entry provides access to several AGC parameters, each of which starts
with
. For most purposes the defaults will suffice. Tap the
A G C *
switches to access the following parameters (defaults in parentheses):
(007): Threshold at which AGC action begins. A higher number
A G C *TH R
1
moves the threshold up, providing greater audio dynamic range.
(215): Rate of AGC attack. A lower number than the default
A G C *A TK
2
provides a softer attack but may also result in overshoot.
(000): Hold time in seconds for voice modes. Prevents AGC
A G C *H LD
3
decay for a specified time after attack, reducing AGC interaction with signals.
(Fast, 140; Slow, 040): Specifies the decay rate for slow or fast
A G C *D C Y
4
AGC (see AGC SPD menu entry). A larger number means a faster decay.
(015): The higher the slope number, the "flatter" the AGC
A G C *SLP
5
response is. With a high setting of slope, signals above the AGC threshold will be
held close in audio amplitude even if they vary in strength at the RF input.
(NOR): Noise pulse rejection. Prevents the AGC (and S-meter)
A G C *PLS
6
from charging up on one-shot noise events. Set it to OFF to disable this feature.
Set alarm/Auto-Power-On time. Tap
.
. If a KXBC3 option module is installed and an internal battery is
H H
MM
installed, time will be maintained when power to the transceiver is turned off.
Otherwise the time registers will reset to
At the alarm time, the KX3 will emit three short beeps. If power had been turned
off, AF output will then be restored to the last-used level.
Set to
if AM operation is not planned. You can still copy AM signals using
O FF
SSB modes even if AM is turned off.
KXAT3 ATU mode (or KXAT100, if connected to the KX3). This is normally set
to
or
. Modes
B YP
A U T O
relays and L-network. Tapping
If set to
, the KX3 will send band data ("automatic info") to its
A N T C TR L
ACC1 jack for use with devices such as SteppIR™ antennas. The data is sent on
every band change, and once per second if the VFO is being moved. See pg. 28.
If set to
, the KX3 will function as a front panel for remote control of
R IG C TR L
a second KX3 (or a K3) via an internet or wiFi connection. See pg. 28.
Sets auto-power-off time in minutes (the timer is retriggered when any control is
used, and during transmit). If set to
setting of
or
minutes is recommended when running from batteries.
5
1 0
If the KXBC3 option is installed (NiMH charger and real-time clock), set to
. Other settings are used for battery charging; see pg. 24.
N O R
Low-battery warning threshold. The default (
some 12 V batteries. For NiMH internal batteries, a setting of
recommended. For internal alkaline or nonrechargeable lithium batteries,
If the internal battery or external supply/battery voltage drops below this level, the
operator will be alerted with a
if the supply voltage drops below 8.0 V. For tips on extending battery life, see pg.
24.
LCD backlight on/off. The display is transflective, so it can be seen in sunlight
with the backlight turned off. Turning it off will extend battery life.
A G C S
to turn alarm on/off; tap
1
0 0 : 0 0 : 0 0
,
, and
L1 - L8
C 1 - C 8
clears stored LC data for the present band.
C L R
, power is never turned off. A
IN F IN ITE
1 0 . 0
message. The KX3 will turn itself off
B A T LO W
36
, and for other
FA S T
and
display icons.
F
through
1
/
to set
2
3
on power-up.
are used to test the KXAT3's
C t
volts) is sufficient for use with
V is
8 .5
6
V.
9 .0