Download Print this page
ProMariner TruePower Combi Owner's Manual And Installation Manual

ProMariner TruePower Combi Owner's Manual And Installation Manual

1000-2500 watts 12/24 volts combination battery charger / inverter

Advertisement

Quick Links

Visit ProMariner Online at www.promariner.com, for a Complete
Selection of Quality Marine Products...
Here are just a few:
ProMite Series - Recreational Grade Waterproof Marine Battery Chargers
ProTournament Series - Professional Grade Waterproof Marine
Battery Chargers
ProSport Series - Heavy Duty Recreational Grade Waterproof
Marine Battery Chargers
3
ProNautic C
Series All Digital Dry Mount Battery Chargers
ProTech-i Series Dry Mount Battery Chargers
Digital Mobile Charge In-Transit Chargers
TruePower Marine Inverters
Battery Maintainers
AC Plug Holders
Battery Isolators
Isolation Transformers
FailSafe Galvanic Isolators and Monitored Systems
Corrosion Control Products
Waterproof Marine Binoculars
A Complete Line of Hand Held Test Meters
Online Technical Support and Service Support
Visit frequently, we are always adding new products for your
boating enjoyment!
Factory Service
TEL: 1-800-824-0524
www.promariner.com
8:30 - 5:00 Eastern Standard Time
200 International Drive, STE 195
Portsmouth, NH 03801
specifications subject to change without notice
010909
TruePower Combi
Owner's Manual and Installation Guide
1 0 0 0 - 2 5 0 0
W a t t s
Combination Battery Charger / Inverter
Please read thoroughly prior to installation
Contains Important Installation and Operation Information and instructions for:
QS Series - Quasi (Modified) Sine Wave Series
PS Series - Pure Sine Wave Series
IMPORTANT NOTICE - SAVE THESE INSTRUCTIONS
Please save and read all safety, operating and installation instructions before installing
or applying DC or AC power to your TruePower Combi.
Your Satisfaction is Important to Us!
Do Not Return this Product to the Retailer or Dealer for any service or warranty requirements.
Please call our Customer Care Department line at 1-800-824-0524 from 8 am to 5 pm (Eastern
Standard Time) for any warranty, service or installation assistance you may need. Thank You
|
1 2 / 2 4
V o l t s

Advertisement

loading
Need help?

Need help?

Do you have a question about the TruePower Combi and is the answer not in the manual?

Questions and answers

Summary of Contents for ProMariner TruePower Combi

  • Page 1 Please save and read all safety, operating and installation instructions before installing Visit frequently, we are always adding new products for your or applying DC or AC power to your TruePower Combi. boating enjoyment! Your Satisfaction is Important to Us!
  • Page 2 Two Year Limited Factory Warranty Setup And Operation... 9-14 Each TruePower Combi model is guaranteed against defects in material and workmanship to the original Installation... 14-26 consumer in normal use for 2 years from the date of purchase. Professional Mariner, LLC will at it's discretion repair or replace free of charge any defects in material or workmanship.
  • Page 3 4) Relocate the affected appliance so it is further separated from the TruePower Combi Charger/Inverter DC Voltage DC Amps TruePower Combi - Combination Charger / Inverter with Automatic Crossover (range) (max continuous) This equipment has been designed to comply with: (110 VAC 60 Hz.) 12 Volt QS Models...
  • Page 4 THIS UNIT IS NOT IGNITION PROTECTED Efficiency >80% Cooling Fan SAVE THESE INSTRUCTIONS – This manual contains important safety, operating and installation instructions for these TruePower Combi models: Short Circuit Protection Soft Start TruePower Combi - Combination Charger/Inverter High Voltage Protection...
  • Page 5 Do not operate the unit if it has been dropped or visibly damaged in any way 10,000 or less 80% of rating Do not disassemble the unit. If service or repair is required please contact ProMariner 10,001 – 12,500 8,000 customer service at 1-800-824-0524 12,501 –...
  • Page 6: Personal Safety Precautions

    P e r s o n a l S a f e t y P r e c a u t i o n s A p p e n d i x 1 Personal Safety Precautions Appendix 1 Load Calculations HELP - Someone should be within the range of your voice or close enough to come to LEG A LEG B...
  • Page 7 11.8.2.2.1.4 Load Factor INVERTER – The TruePower Combi serves as a Pure Sine wave or a Quasi (modified) Sine Formula: wave inverter, converting DC power to clean, reliable AC power. First 2,000 total watts at 100% = _________.
  • Page 8: Troubleshooting

    Fault Condition, See Troubleshooting Section BEEP 0.5 SEC Pass NOTE: This panel is removable from the TruePower Combi unit to be located in an area of Through FOR 1 SEC. greater convenience. A dummy plate is included in the package. See the Installation Over BEEP 0.5 SEC...
  • Page 9 ProMariner. 2. DC Positive and Negative Connections The first step to any problem is resetting the TruePower Combi unit by turning off and Corrosion Resistant Mounting Studs, Provided with Multi-Directional Protective Cover. (See then on the switch located on the remote panel.
  • Page 10 Post Installation Features 3. Auto Cooling Fan Your TruePower Combi Includes a Cooling Fan that is operational in both Invert and Charge POST INSTALLATION PRE-START CHECKLIST: mode. The fan keeps the TruePower Combi at an acceptable temperature. The fan operation VERIFY: is dependant upon unit temperature, charge current, and inverter load.
  • Page 11 (e.g. a separate breaker Electrical Shock Hazard on an AC panel board) to the TruePower Combi. The presence of AC current begins the Vessel is equipped with a DC to AC power inverter charging cycle, as well as indicates to the whole system that the inverter is NO LONGER Disconnect inverter DC input before servicing vessel’s electrical systems.
  • Page 12: Setup And Operation

    Different batteries are charged with dramatically different charging profiles. A change in battery type upon replacement will require resetting 1500 150A of the battery type on the TruePower Combi unit. Identifying the battery type (available on the 2000 200A 100A...
  • Page 13: Setup And Operation

    INSTALLATION MATERIALS – CABELING on the remote panel is in the Off position. 1) DC Cables - The DC portion of the TruePower Combi requires a large amount Turn off the AC main shore/station power breaker. of amperage in Inverter Mode. Cable size and length is of extreme importance...
  • Page 14 Earth Safety Ground connected to the boats Green or Green The TruePower Combi can be used to power any number of AC appliances normally only DC grounding bus. This conductor is essential to w/ Yellow Stripe available to you while hooked to shore/station power or operating a generator. Appendix shock and fire prevention and carries current A includes a load calculation sheet from ABYC E-11 AC &...
  • Page 15 TruePower Combi inverter. The TruePower does include low battery protection to prevent complete discharge of your DC system. It is extremely difficult to predict how long the attached DC battery bank (no matter what size or type) will sustain the use of the inverter connected loads.
  • Page 16 Setup and Operation the end of this manual for future reference. This load vs. time ratio will change as TruePower Combi Installed to Power a Full AC Panelboard - Transfer to All Loads batteries age or are replaced. START UP CURRENT (INRUSH) - Many motor operated appliances have a higher 2) TRANSFER TO ALL LOADS –...
  • Page 17 MOUNTING - This unit is heavy (around 42 pounds) and must be mounted securely to an appropriate surface (e.g. plywood bulkhead, cored fiberglass hull structure) and through-bolted if possible. ProMariner highly recommends using mounting holes other than just the key slots for mounting.
  • Page 18 1) SPLIT BUS – This option allows only certain circuits to be energized by the Status Center Quasi Sine Wave Inverter 3 Stage Battery Charger TruePower Combi. There are several points to make a note of in the following Combination Charger/Quasi Sine Wave Inverter 0. Service DC Input 10.5 V - 15 VDC...
  • Page 19 I n s t a l l a t i o n G u i d e l i n e s Installation Installation 3) Disconnect the short pigtail from inside the TruePower Combi. 1. Network-Type Cable Connection Network-Type Cable Connection DETAIL 1) Locate remote panel and prepare an appropriately sized mounting location (75mm x 44mm or 3”...