Requirements for brewers with an attached cord set are as follows:
Note: This electrical service re-
quires 2 current carrying conduc-
tors (Neutral, and L1) and a separate
conductor for earth ground.
WHITE
WHITE
NEUTRAL
NEUTRAL
L1 BLACK
L1 BLACK
GREEN
Requirements for brewers without an attached cord set are as follows:
Note: This electrical service
require 3 current carrying
conductors (Neutral, L1 and
L2) and a separate conductor
for earth ground
L2 RED
L2 RED
WHITE
WHITE
NEUTRAL
NEUTRAL
L1 BLACK
L1 BLACK
GREEN
ELECTRICAL REQUIREMENTS
Single & Dual Volt
N
120V. A.C.
L1
GREEN
120V AC
G
Single phase models
L2
120V. A.C.
208 or 240V. A.C.
N
120V. A.C.
L1
GREEN
G
120/208 & 120/240V AC
Single phase models
Page 5
Dual Voltage Switch
in 120V position
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90 C (194 F)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
Dual Voltage Switch in
120/208-240V position
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90 C (194 F)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS