VCF 1 and 2 Filter PCB
There are several configuration options on the filter PCB. These are maximum resonance limit, VCF filter disable,
and change default MIDI setup (Filter 2 Only). To disable the functions plug the jumpers on to one leg of the
connector. This retains them for future use if needed.
Filter Disable
A
Refer to detail
locate and remove the jumper sleeve to prevent the filter from being switched on. Maximum
filter resonance can be limited by removing the two jumper sleeves illustrated (also in detail
MIDI - Filter 2 only
B
Refer to detail
: A four way dip switch selects which controls on the XONE:92 output MIDI data. The default
setting is all ON, set each switch to off to prevent the associated control from sending MIDI controller messages.
The MIDI output channel is set to 16 as a factory default; this can be changed to 15 by changing over the
"CHANNEL" dip switch.
The Tempo/Data controller default configuration provides a means of fine tuning the MIDI clock speed. This
control can be reconfigured as a dedicated Data send (CC94) by moving the jumper sleeve for VR4 from the T
(Tempo) position to the D (Data) position.; right hand side of detail
clocks will still be transmitted via LFO 2 tap tempo button.