Other Operation Modes; Start Up Operation (D); Defrost Operation (D); Quiet Mode Operation (S) - Daikin EKHVMRD50AAV1 Operation Manual

Altherma indoor unit
Table of Contents

Advertisement

4.7. Other operation modes

Start up operation (d)

During start up, the d icon displays, indicating that the heat
pump is starting up and is not working in a steady state condition.

Defrost operation (d)

In space heating operation or domestic water heating operation,
freezing of the outdoor heat exchanger may occur due to low outdoor
temperature. If this risk occurs, the system goes into defrost
operation. During defrost operation, space heating or domestic hot
water operation is not possible.

Quiet mode operation (s)

Quiet mode operation means that the indoor unit works at reduced
compressor speed so that the noise produced by the indoor unit
drops. This implies that it will take longer till the required temperature
set point is reached. Beware of this when a certain level of heating is
required indoors.
Selecting quiet mode operation
1
Use the s button to activate quiet mode operation.
The s icon displays.
If the controller is set to permission level 2 or 3 (refer to "Field
settings" in the installation manual), the s button is not
operable.
Press the s button again to deactivate quiet mode operation.
2
The s icon disappears.
There are 3 different levels of quiet mode operation. The desired
quiet mode is set through a field setting. Refer to
settings" on page 19
for a detailed description how to set one or more
field settings.
[8-03] Status: defines the level of low noise operation (quiet
mode).
EKHVMRD50+80AAV1 + EKHVMYD50+80AAV1
Daikin Altherma indoor unit
4PW61264-1A – 10.2010
4.8. Simultaneous demand of space heating and
domestic water heating
The unit can not perform domestic water heating and space heating
at the same time. If both modes are requested at the same time, the
unit will heat up till the reheat maximum temperature in 1 time. During
this period, space heating is not possible.
If you are using the remote controller room temperature control:
When the reheat temperature is reached, the further heat up of
the domestic hot water tank will be decided by the remote
controller room thermostat in order to prevent the room
temperature to drop too much.
If you are using the external room thermostat:
When the reheat temperature is reached, the further heat up of
the domestic hot water tank will be decided by the external room
thermostat thermo conditions and running timers which are
programmed by your installer.
If you are using the remote controller leaving water temperature
control:
When the reheat temperature is reached, the further heating up
of the domestic hot water tank will be decided by the running
timers which are programmed by your installer.
T
A
B
A
Storage temperature
"4.15. Field
B
Reheat maximum temperature
t
Time
T
Domestic hot water storage temperature
4.9. Simultaneous demand of space cooling and
domestic water heating
The unit can perform simultaneous operation of cooling and domestic
water heating.
During cooling operation, the energy taken from the cooled water will
be transferred into energy to heat up the domestic water. It is a
recovery function and is controlled automatically by the system.
This heat recovery is only possible if heat recovery operation is
permitted (it is an installation related setting).

4.10. Temperature read-out mode

On the remote controller, the actual temperatures can be displayed.
1
Push and hold the ba button for 5 seconds.
The heating/cooling leaving water temperature is displayed
(icons l and = and é are blinking).
2
Use the pi and pj buttons to display:
■ The entering water temperature (icons l and = are
blinking and the é icon is flashing slowly).
■ The indoor temperature (icons l and = are blinking).
■ The outdoor temperature (icons l and u are blinking).
■ The hot water supply tank temperature (icons l and w are
blinking).
Push the ba button again to leave this mode. If no button is
3
pressed, the remote controller leaves the display mode after 10
seconds.
t
Operation manual
10