Compact design fits on/under your desk; can also be mounted to a wall Unit inspection Once you have received the Powerware 3105 UPS product, you should remove and inspect the product for shipping damage. If any damage is found, please notify the carrier and your dealer.
” 1. Place the Powerware 3105 UPS indoors in an area that has adequate airflow and is free of excessive dust. Do NOT allow the UPS to be exposed to moisture, rain, excessive heat, or direct sunlight.
Principal shown below for detailed information how to connect please refer to battery replacement section. Installation and Operation: Following steps explain how to connect and operate the Powerware 3105 UPS. 1. Connect the UPS to a grounded power outlet. Note It is recommended that the battery should be charged for minimum 8 hours to ensure full charge before placing the UPS in service.
Typical applications Indicators 1. On/Off Push Button/Test Switch One switch controls the power to your equipment. Upon power turn on, unit performs a self-test to detect overload or undercharged conditions. Turn on the UPS Press and hold the push button switch depressed for more than one second. Release the switch after the audible beep is sounded.
2. On/Off Battery LED Indicates the UPS is on and is powering your equipment. A constantly illuminated LED indicates normal utility power operation. A blinking LED indicates that the UPS is providing power from its battery. 3. Fault/Warning LED Indicates a fault or warning condition is present. A constantly illuminated LED indicates a LOW battery condition.
350VA and 500VA models (12V-4.5Ah,or 5Ah battery) 700VA model (12V- 7Ah battery) Status Indicators The UPS provides both visual and audible status indicators. Visual indicators consist of three LEDs to represent the following conditions: • On utility power operation • On battery power operation •...
LED & Alarm Status Table UPS status Green LED Red LED Buzzer Self test Blink 1 (by turns) Charging Charge off AC (Utility mode Low battery Blink 2 Over load Blink 2 Normal Blink 2 DC (Battery Over load Blink 2 Mode) Low battery Blink 2...
Troubleshooting Symptom Possible Cause Action to Take The battery is disconnected Connect the battery (see Connect Battery) and utility power is not and ensure power is available at the wall available at the wall outlet. outlet. UPS will not turn on. Reduce the amount of equipment plugged into Input Circuit Breaker has the outlets of the UPS.