Daikin EKHBH030BA Operation Manual page 5

Indoor unit for air to water heat pump system and options
Hide thumbs Also See for EKHBH030BA:
Table of Contents

Advertisement

Available languages

Available languages

6.
CLOCK DISPLAY
8
The clock display shows the current time.
When reading or programming the schedule timer, the clock
display shows the action time.
7.
SCHEDULE TIMER ICON
p
This icon indicates that the schedule timer is enabled.
8.
ACTION ICONS
q
These icons indicate the programming actions for each day of
the schedule timer.
9.
OFF ICON
x
This icon indicates that the OFF action is selected when
programming the schedule timer.
10. INSPECTION REQUIRED
These icons indicate that inspection is required on the
installation. Consult your dealer.
11. SET TEMPERATURE DISPLAY
The display shows the current space heating/cooling set
temperature of the installation in °C or °F.
12. SETTING
$
Not used. For installation purposes only.
13. NOT AVAILABLE
n
This icon is displayed whenever a non-installed option is
addressed or a function is not available.
14. DEFROST/STARTUP MODE ICON
This icon indicates that the defrost/startup mode is active.
15. COMPRESSOR ICON
ç
This icon indicates that the compressor in the outdoor unit of the
installation is active.
16. BACKUP HEATER STEP ONE
These icons indicate that the backup heater is operating on low
capacity (
(
) or on high capacity (
provides extra heating capacity in case of low ambient outdoor
temperature (high heating load).
17. BOOSTER HEATER ICON
This icon indicates that the booster heater is active. The booster
heater provides auxiliary heating for the domestic hot water
tank.
The booster heater is located in the domestic hot water tank.
The icon is not used when the domestic hot water tank is not
installed.
é
18. PUMP ICON
This icon indicates that the circulation pump is active.
19. OUTDOOR TEMPERATURE DISPLAY
When this icon is flashing, the outdoor ambient temperature is
displayed.
20. WEATHER DEPENDENT SET POINT ICON
This icon indicates that the controller will adapt the temperature
set point automatically, based on the outdoor ambient
temperature.
21. TEMPERATURE ICON
b
This icon is displayed when the water outlet temperature of the
indoor unit, the outdoor ambient temperature and the domestic
hot water tank temperature are shown.
The icon is also displayed when the temperature set point is set
in schedule timer programming mode.
22. TEST OPERATION ICON
t
This icon indicates that the unit runs in test mode.
23. FIELD SET CODE
;
This code represents the code from the field set list. Refer to the
"Field settings table" on page 15.
EKHBH/X030BA
Indoor unit for air to water heat pump system and options
4PW62569-1 – 07.2010
k
and
l
d
(
OR STEP TWO
§
§
). The backup heater
m
u
a
24. ERROR CODE
:
This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.
25. SPACE HEATING/COOLING BUTTON
This button allows manual switching between heating or cooling
mode (provided the unit is not a heating only unit).
When the unit is connected with an external room thermostat,
this button is not operable and the icon
26. DOMESTIC WATER HEATING BUTTON
This button enables or disables heating of the domestic water.
This button is not used when the domestic hot water tank is not
installed.
Remark that pushing the
the domestic water heating. Domestic water heating is only
switched on or off by means of the
27. WEATHER DEPENDENT SET POINT BUTTON
This button enables or disables the weather dependent set point
function which is available in space heating operation only.
If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 12), the weather dependent set point button
will not be operable.
28. INSPECTION/TEST OPERATION BUTTON
This button is used for installation purposes and changing field
settings. Refer to "Field settings" on page 12.
29. PROGRAMMING BUTTON
This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.
30. SCHEDULE TIMER BUTTON
The main function of this multi-purpose button is to
enable/disable the schedule timer.
The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.
If the controller is set in permission level 3 (refer to "Field
settings" on page 12), the schedule timer button will not be
operable.
31. TIME ADJUST BUTTON
pi
These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water outlet temperature of the
indoor unit, outdoor ambient temperature and domestic hot
water temperature) and in schedule timer programming mode.
32. TEMPERATURE ADJUST BUTTONS
These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.
33. DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS
wbi
wbj
and
These buttons are used to adjust the current set point of the
domestic hot water temperature.
The buttons are not used when the domestic hot water tank is
not installed.
34. QUIET MODE BUTTON
s
This button enables or disables quiet mode.
If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 12), the quiet mode button will not be
operable.
=
e
is shown.
v
y
button has no influence on
v
button.
ba
z
<
r
/
p
and
pj
bi
and
bj
Operation manual
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhbx030ba

Table of Contents