Field settings table

Temperature values displayed on the digital controller (user interface) are default in °C.
To change the display to °F, push ib and jb buttons simultaneously for 5 seconds. Execute same procedure to change back to
the °C display.
First
Second
code
code
Setting name
0
User permission level
00
User permission level
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_TI)
03
Set point at high ambient temperature (Hi_TI)
2
Disinfection function
00
Operation interval
01
Status
02
Start time
03
Set point
04
Interval
3
Auto restart
00
Status
4
Space heating off temperature
00
Installation related setting
01
Installation related setting
02
Space heating off temperature
03
Installation related setting
04
Installation related setting
5
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
6
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
7
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
8
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
Operation manual
15
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
3
2/3
14
–4~41
(–10)
(–20~5)
59
50~68
(15)
(10~20)
104
77~131
(40)
(25~55)
77
77~131
(25)
(25~55)
Mon~Sun,
Fri
All
1 (ON)
0/1
23:00
0:00~23:00
158
104~176
(70)
(40~80)
10
5~60
0 (ON)
0/1
77
57.2~77
(25)
(14~25)
Indoor unit for air to water heat pump system and options
Step
Unit
1
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1.8
°F
(1)
(°C)
1:00
hour
9
°F
(5)
(°C)
5
min
1.8
°F
(1)
(°C)
EKHBH/X030BA
4PW62569-1 – 07.2010