Control Heat Source/Heat Method - Pentair i-Link User Manual

Intellitouch protocol interface adapter
Table of Contents

Advertisement

Control Heat Source/Heat Method

POOLHT:
POOLHT2:
SPAHT:
SOLHT:
SPASOLHT:
SOLPREF:
SPASOLPREF: Enable/Disable Spa Solar Preferred
Note: POOLHT is used in this example.
Request State:
Query:
Response:
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Set State:
Command:
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Response:
Toggle State:
Toggle:
Response:
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Note: Turning POOLHT ON will enable the heater, and disable solar
option.
Turning POOLHT OFF will disable all heat sources for pool.
Turning SOLHT ON will select the SOLAR ONLY option of the
IntelliTouch.
Turning SOLPREF ON will select the SOLAR PREFERRED option of
the IntelliTouch. The same rules apply for the Spa options
Enable/Disable Pool Heater
Enable/Disable High Pool Heater
Enable/Disable Spa Heater
Enable/Disable Pool Solar
Enable/Disable Spa Solar
Enable/Disable Pool Solar Preferred
#POOLHT ?<cr>
!00 POOLHT = x<cr>
!00 x<cr>
#POOLHT = x<cr>
!00 POOLHT = x<cr>
!00 x<cr>
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
#POOLHT <cr>
!00 POOLHT = x<cr>
!00 x<cr>
IntelliTouch i-Link Protocol Interface Adapter User's Guide
(RSPFMT = 0)
(RSPFMT = 1)
(RSPFMT = 0)
(RSPFMT = 1)
(RSPFMT = 0)
(RSPFMT = 1)
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellitouch i-link