Spillway: Wfall: Waterfall/Spillway Control - Pentair i-Link User Manual

Intellitouch protocol interface adapter
Table of Contents

Advertisement

SPILLWAY
WFALL:
Waterfall/Spillway Control
Control/Query/Toggle Pump (pool).
Request State:
Query:
Response:
Set State:
Command:
Response:
Toggle State:
Toggle:
Response:
Note: The WFALL commands assume a circuit has been configured as a
Waterfall. If there are circuits configured, the response will be an error
message.
?23 OPTION SWITCH NOT SET
Note: The keyword WFALL and SPILLWAY are interchangeable.
#WFALL ?<cr>
!00 WFALL = x<cr>
!00 x<cr>
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
#WFALL = x<cr>
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
!00 WFALL = x<cr>
!00 x<cr>
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
#WFALL <cr>
!00 WFALL = x<cr>
!00 x<cr>
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
IntelliTouch i-Link Protocol Interface Adapter User's Guide
(RSPFMT = 0)
(RSPFMT = 1)
(RSPFMT = 0)
(RSPFMT = 1)
(RSPFMT = 0)
(RSPFMT = 1)