POOLSP:
Temperature Set Point Control
POOLSP2:
SPASP: POOLSP is used for the example
Request State:
Query:
Response:
Where xx is the current temperature value (in ASCII) of the pools desired
heating set point.
Set Value:
Command:
Where xx is the desired temperature
Response:
Where xx is the current temperature value (in ASCII) of the Pools desired
heating set point.
Note: POOLSP2 is valid only on Models i9+3S and i5S. It is used
to set the High Temperature. It is equivalent. To SPASP.
POOLSP+:
POOLSP-:
SPASP+:
SPASP-:
Inc/Dec Value:
Command:
Response:
Where xx is the current temperature value (in ASCII) of the Pools desired
heating set point.
IntelliTouch i-Link Protocol Interface Adapter User's Guide
Control/Query Temperature Set Point.
#POOLSP ?<cr>
!00 POOLSP = xx<cr>
!00 xx<cr>
#POOLSP = xx<cr>
!00 POOLSP = xx<cr>
!00 xx<cr>
Inc/Dec temperature Set Point
POOLSP+ is used for the example
#POOLSP+<cr>
!00 POOLSP = xx<cr>
!00 xx<cr>
(RSPFMT = 0)
(RSPFMT = 1)
(RSPFMT = 0)
(RSPFMT = 1)
(RSPFMT = 0)
(RSPFMT = 1)