B. Design and Installation Considerations
NOTICE: Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
Before installing, determine the following:
Where the fireplace is to be installed
The vent system configuration to be used
Gas supply piping
Electrical wiring
Framing and finishing details
Whether optional accessories—devices such as a fan,
wall switch or remote control —are desired
NOTICE: Junction box should be installed during initial
setup to avoid major reconstruction.
C. Draft
Draft is the pressure difference needed to vent fireplaces
successfully. When a fireplace is drafting successfully, all
combustion byproducts are exiting the home through the
chimney.
Considerations for successful draft include:
Preventing negative pressure
Location of fireplace and chimney
NOTICE: Hearth & Home Technologies assumes no
responsibility for the improper performance of the fireplace
system caused by:
Inadequate draft due to environmental conditions
Downdrafts
Tight sealing construction of the structure
Mechanical exhausting devices
Improper location of the chimney
Page 32
Heat & Glo • NorthStar EPA Fireplace • 480-1081E
D. Negative Pressure
WARNING! Risk of Asphyxiation! Negative pressure
can cause spillage of combustion fumes and soot. Fire
must draft properly for safe operation.
Negative pressure results from the imbalance of air avail-
able for the fireplace to operate properly. It can be stron-
gest in lower levels of the house.
Causes include:
Exhaust fans (kitchen, bath, etc.)
Range hoods
Combustion air requirements for furnaces, water heaters
and other combustion appliances
Clothes dryers
Location of return-air vents to furnace or air conditioning
Imbalances of the HVAC air handling system
Upper level air leaks such as:
- Recessed lighting
- Attic hatch
- Duct leaks
To minimize the effects of negative air pressure:
Install the outside air kit with the intake facing prevailing
winds during the heating season
Ensure adequate outdoor air for all combustion
appliances and exhaust equipment
Ensure furnace and air conditioning return vents are not
located in the immediate vicinity of the fireplace
Avoid installing the fireplace near doors, walkways or
small isolated spaces
Recessed lighting should be a "sealed can" design
Attic hatches weather stripped or sealed
Attic mounted duct work and air handler joints and seams
taped or sealed
Basement installations should be avoided
NOTICE: Hearth & Home Technologies Inc. recommends
the use of direct vent fireplaces in basements.