USING YOUR MicroSentry™ REFRIGERATION MONITOR
Door Switch
Light Switch
NOTE
During initial startup, or anytime power is interrupted,
there will be an approximate 5 minute delay before the
refrigerator starts. During this period the controller will
be assessing the temperature in the refrigerator and the
display will appear erratic, this is normal. The desired
temperature set point can be programmed during this
start up period.
Starting your refrigerator
The refrigerator will begin start up when initially plugged in
or when power resumes after a power outage. At this time
the refrigerator will take approximately 5 minutes to begin
running as noted above. If the refrigerator has been turned
off during use, "OFF" will appear on the display. To start the
refrigerator from the "OFF" position press and hold the ON/
OFF button for 3 seconds.
Set temperature
To set temperature set point, press and continue to hold
"SET" button. After one second, set point will be displayed.
While holding "SET" button use the "WARMER" or "COLD-
ER" button to desired set point.
NOTE: Momentarily pressing & releasing "SET" button will
access information menu of control. Refer to appendix A for
information on this feature.
Refrigerator operation
The available temperature range of the refrigerator is 4° to
18° C.
It may take up to 24 hours for your refrigerator to reach de-
sired temperature. This will depend on amount of contents
loaded and number of openings and closings of the door.
For best results allow refrigerator to "pull down" to desired
set point before loading. Once contents are loaded, allow
at least 48 hours for temperature to stabilize before making
any adjustments to the set point.
5
Alarms
Your MicroSentry™ refrigerator control will monitor refrig-
erator function and alert you with a series of audible and
visual alarms.
• Door Ajar Alarm: If the door has been left
open for over five (5) minutes, the alarm
will sound in one (1) second intervals. The
display panel will flash "do" and the LED light will be a
steady amber color. This will stop as soon as the door is
closed.
• High and Low Temperature Alarm: If your
unit reaches an unacceptable temperature
outside of your set point, the alarm will
sound in one (1) second intervals. The
display panel will flash either "hi" or "Lo"
depending upon the condition and the LED light will be a
steady amber color. "hi" indicates that the temperature is
5.5°C above the set point and "Lo" indicates that the tem-
perature is 5.5°C below the set point. The alarm will remain
active until the condition is corrected.
NOTE
During initial appliance start-up, the high temperature alarm
may sound until the interior temperature reaches set point.
• Temperature Sensor Fault: If the controller
detects that the temperature sensor is
not properly functioning, a temperature
sensor alarm will sound. "E1" will flash on the display, and
an alarm will sound. Please call Rangemaster Customer
Service or your dealer if this error code is displayed.
• Condenser Needs Cleaning:
When the refrigerator has reached the
recommended amount of run time to ne-
cessitate cleaning the air flow, "cL" will flash on the display
as a reminder. See the "Care and Cleaning" section for
cleaning instructions.
To clear the alarm:
Control